{"product_id":"sonde-zur-messung-von-temperatur-und-feuchtigkeit","title":"Sensor for measuring temperature and humidity","description":"\u003ch1 data-start=\"136\" data-end=\"183\"\u003e\u003cstrong data-start=\"138\" data-end=\"183\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eTemperature and humidity controller HT-310 TENSE\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"185\" data-end=\"206\"\u003e\u003cstrong data-start=\"188\" data-end=\"206\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"207\" data-end=\"400\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelay for temperature and humidity control. The humidity and temperature controller has separate outputs, hysteresis adjustment, and is designed for flush mounting. Device dimensions: \u003cstrong data-start=\"377\" data-end=\"397\"\u003e72 × 36 × 100 mm\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"402\" data-end=\"569\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThis controller is suitable for controlling air conditioning, heating systems, dehumidifiers, heaters, and other processes where temperature and humidity need to be measured and controlled.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"576\" data-end=\"605\"\u003e\u003cstrong data-start=\"579\" data-end=\"605\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"607\" data-end=\"1643\"\u003e\n\u003cli data-start=\"607\" data-end=\"667\"\u003e\n\u003cp data-start=\"609\" data-end=\"667\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"609\" data-end=\"625\"\u003eSensor type:\u003c\/strong\u003e NT-310 (common for temperature and humidity)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"668\" data-end=\"729\"\u003e\n\u003cp data-start=\"670\" data-end=\"729\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"670\" data-end=\"696\"\u003eTemperature measurement range:\u003c\/strong\u003e -19.9 °C ... +80.0 °C; 1 °C step\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"730\" data-end=\"782\"\u003e\n\u003cp data-start=\"732\" data-end=\"782\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"732\" data-end=\"759\"\u003eHumidity measurement range:\u003c\/strong\u003e 5% ... 95%; step 1\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"783\" data-end=\"813\"\u003e\n\u003cp data-start=\"785\" data-end=\"813\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"785\" data-end=\"804\"\u003eControl principle:\u003c\/strong\u003e ON-OFF\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"814\" data-end=\"973\"\u003e\n\u003cp data-start=\"816\" data-end=\"830\"\u003e\u003cstrong data-start=\"816\" data-end=\"828\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOutputs:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"833\" data-end=\"973\"\u003e\n\u003cli data-start=\"833\" data-end=\"900\"\u003e\n\u003cp data-start=\"835\" data-end=\"900\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e°C OUT: switching control contact, 2A resistive load for temperature\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"903\" data-end=\"973\"\u003e\n\u003cp data-start=\"905\" data-end=\"973\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e%RH OUT: normally open contact, 2A resistive load for humidity\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"1073\"\u003e\n\u003cp data-start=\"976\" data-end=\"998\"\u003e\u003cstrong data-start=\"976\" data-end=\"996\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating modes:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1001\" data-end=\"1073\"\u003e\n\u003cli data-start=\"1001\" data-end=\"1033\"\u003e\n\u003cp data-start=\"1003\" data-end=\"1033\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTemperature: cooling\/heating\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1036\" data-end=\"1073\"\u003e\n\u003cp data-start=\"1038\" data-end=\"1073\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHumidity: dehumidification\/humidification\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1074\" data-end=\"1138\"\u003e\n\u003cp data-start=\"1076\" data-end=\"1138\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1090\"\u003eHysteresis:\u003c\/strong\u003e separately adjustable for temperature and humidity\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1139\" data-end=\"1222\"\u003e\n\u003cp data-start=\"1141\" data-end=\"1222\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1141\" data-end=\"1151\"\u003eALARM:\u003c\/strong\u003e selection between absolute, relative temperature or sensor error\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1223\" data-end=\"1290\"\u003e\n\u003cp data-start=\"1225\" data-end=\"1290\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1225\" data-end=\"1250\"\u003eON\/OFF Delay:\u003c\/strong\u003e for cooling operation (e.g., compressors)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1291\" data-end=\"1385\"\u003e\n\u003cp data-start=\"1293\" data-end=\"1385\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1293\" data-end=\"1309\"\u003eFixed Offset:\u003c\/strong\u003e adjustable for temperature or humidity when changing sensor cable length\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1386\" data-end=\"1443\"\u003e\n\u003cp data-start=\"1388\" data-end=\"1443\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1388\" data-end=\"1407\"\u003ePassword protection:\u003c\/strong\u003e security of the configured parameters\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1444\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1446\" data-end=\"1516\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1446\" data-end=\"1456\"\u003eMemory:\u003c\/strong\u003e non-volatile EEPROM memory for storing settings\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1517\" data-end=\"1605\"\u003e\n\u003cp data-start=\"1519\" data-end=\"1605\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1519\" data-end=\"1533\"\u003eConnection:\u003c\/strong\u003e easy disconnect\/connect to the controlled device via quick couplings\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1606\" data-end=\"1643\"\u003e\n\u003cp data-start=\"1608\" data-end=\"1643\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1608\" data-end=\"1621\"\u003ePower supply:\u003c\/strong\u003e 100-240 V, 50-60 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1650\" data-end=\"1664\"\u003e\u003cstrong data-start=\"1653\" data-end=\"1664\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUsage\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1665\" data-end=\"1693\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller can be used as:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1694\" data-end=\"1841\"\u003e\n\u003cli data-start=\"1694\" data-end=\"1758\"\u003e\n\u003cp data-start=\"1696\" data-end=\"1758\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHygrostat \/ hygrometer \/ moisture meter \/ density meter (hygrometer)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1759\" data-end=\"1787\"\u003e\n\u003cp data-start=\"1761\" data-end=\"1787\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThermostat \/ thermal relay\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1788\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1790\" data-end=\"1841\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelay for measuring humidity and air temperature\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1848\" data-end=\"1878\"\u003e\u003cstrong data-start=\"1851\" data-end=\"1878\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSafety notice\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1879\" data-end=\"2496\"\u003e\n\u003cli data-start=\"1879\" data-end=\"2019\"\u003e\n\u003cp data-start=\"1881\" data-end=\"2019\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePay attention to the polarity when connecting the temperature sensor; incorrect connection can damage the sensor or cause the controller to malfunction.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2020\" data-end=\"2133\"\u003e\n\u003cp data-start=\"2022\" data-end=\"2133\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen connecting the controller to the power supply, use a \u003cstrong data-start=\"2078\" data-end=\"2096\"\u003e250 mA \/ 250 V fuse\u003c\/strong\u003e and cables with the appropriate cross-section.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2134\" data-end=\"2180\"\u003e\n\u003cp data-start=\"2136\" data-end=\"2180\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eObserve the electrical safety regulations.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2181\" data-end=\"2339\"\u003e\n\u003cp data-start=\"2183\" data-end=\"2339\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUse shielded, twisted-pair, and grounded cables for the signal contacts. Route the cables away from power lines, shields, and electromagnetic fields.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2340\" data-end=\"2496\"\u003e\n\u003cp data-start=\"2342\" data-end=\"2496\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2342\" data-end=\"2355\"\u003eImportant:\u003c\/strong\u003e The device must be installed in an environment with a temperature of \u003cstrong data-start=\"2409\" data-end=\"2423\"\u003e-20...+55 °C\u003c\/strong\u003e, otherwise the plastic housing may deform and the controller may fail.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51205766938952,"sku":"NT-310","price":35.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/1d3d7c8e7a84bc18e812ada06344ca51.png?v=1755807219","url":"https:\/\/pelek-de.com\/en\/products\/sonde-zur-messung-von-temperatur-und-feuchtigkeit","provider":"Deutschland Pelek","version":"1.0","type":"link"}