{"product_id":"rgt-12svc-blindleistungsregler-12-stufen-tcr-mit-rs485-modbus-rtu","title":"RGT-12SVC - Reactive power controller 12 steps +TCR with RS485 ModBus RTU","description":"\u003ch2 data-start=\"140\" data-end=\"223\"\u003e\u003cfont style=\"font-size: 18px;\"\u003e\u003cstrong data-start=\"143\" data-end=\"223\"\u003e\u003cfont style=\"\"\u003eReactive power controller RGT-12 SVC - 12 steps + SVC, LCD, RS485 MODBUS RTU\u003c\/font\u003e\u003c\/strong\u003e\u003cstrong data-start=\"225\" data-end=\"237\" style=\"color: rgb(78, 86, 95);\"\u003eDimensions\u003c\/strong\u003e\u003cspan style=\"color: rgb(78, 86, 95);\"\u003e 147 × 147 mm\u003c\/span\u003e\u003cstrong data-start=\"253\" data-end=\"265\" style=\"color: rgb(78, 86, 95);\"\u003eManufacturer \u003c\/strong\u003e\u003cspan style=\"color: rgb(78, 86, 95);\"\u003eTENSE (Turkey)\u003c\/span\u003e\u003c\/font\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"290\" data-end=\"312\"\u003e\u003cstrong data-start=\"294\" data-end=\"312\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDevice description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"314\" data-end=\"472\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"314\" data-end=\"328\"\u003eThe RGT-12 SVC\u003c\/strong\u003e is a \u003cstrong data-start=\"332\" data-end=\"366\"\u003e12-step three-phase reactive power compensation controller\u003c\/strong\u003e with a graphic LCD display, compatible with \u003cstrong data-start=\"436\" data-end=\"469\"\u003eSVC (Static VAR Compensation)\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"474\" data-end=\"876\"\u003e\n\u003cli data-start=\"474\" data-end=\"543\"\u003e\n\u003cp data-start=\"476\" data-end=\"543\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIt is used for \u003cstrong data-start=\"485\" data-end=\"540\"\u003ecompensation of both inductive and capacitive reactive power\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"544\" data-end=\"629\"\u003e\n\u003cp data-start=\"546\" data-end=\"629\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen inductive reactive power comes from the grid → the controller switches capacitors in.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"630\" data-end=\"722\"\u003e\n\u003cp data-start=\"632\" data-end=\"722\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen capacitive reactive power comes from the grid → the controller switches on a shunt reactor.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"723\" data-end=\"807\"\u003e\n\u003cp data-start=\"725\" data-end=\"807\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThis effectively reduces the ratio between inductive and capacitive energy and optimizes the power factor.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"808\" data-end=\"876\"\u003e\n\u003cp data-start=\"810\" data-end=\"876\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEnables \u003cstrong data-start=\"819\" data-end=\"875\"\u003eefficient step compensation for unbalanced systems\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"883\" data-end=\"907\"\u003e\u003cstrong data-start=\"887\" data-end=\"907\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhat is an SVC (TCR)?\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"909\" data-end=\"1078\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"909\" data-end=\"916\"\u003eSVC\u003c\/strong\u003e is a static reactive power compensation system with \u003cstrong data-start=\"965\" data-end=\"998\"\u003ethyristor-controlled reactors\u003c\/strong\u003e that enables \u003cstrong data-start=\"1015\" data-end=\"1067\"\u003esmooth and fast compensation of capacitive power\u003c\/strong\u003e in the system.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1085\" data-end=\"1110\"\u003e\u003cstrong data-start=\"1089\" data-end=\"1110\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1112\" data-end=\"2202\"\u003e\n\u003cli data-start=\"1112\" data-end=\"1155\"\u003e\n\u003cp data-start=\"1114\" data-end=\"1155\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e12 relay outputs + SVC (TCR) output\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1156\" data-end=\"1221\"\u003e\n\u003cp data-start=\"1158\" data-end=\"1221\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCan be used with one or three current transformers\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1222\" data-end=\"1298\"\u003e\n\u003cp data-start=\"1224\" data-end=\"1298\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1224\" data-end=\"1244\"\u003e2.9\" LCD display\u003c\/strong\u003e + 17 LED indicators for easy setup and control\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1299\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1301\" data-end=\"1363\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1301\" data-end=\"1321\"\u003eRS485 MODBUS RTU\u003c\/strong\u003e - Remote control, SCADA compatible\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1364\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1366\" data-end=\"1448\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSeparate programmable relay output for alarms (overvoltage, harmonics, cosφ)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1495\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1469\"\u003ePassword protection\u003c\/strong\u003e for parameter settings\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1541\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1541\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of connected compensation stages\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1542\" data-end=\"1598\"\u003e\n\u003cp data-start=\"1544\" data-end=\"1598\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic and manual adjustment of capacitor values\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1599\" data-end=\"1650\"\u003e\n\u003cp data-start=\"1601\" data-end=\"1650\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eControl of even operation of individual stages\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1651\" data-end=\"1718\"\u003e\n\u003cp data-start=\"1653\" data-end=\"1718\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdjustment of response time to changes, discharge time, and stage activation\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1719\" data-end=\"1765\"\u003e\n\u003cp data-start=\"1721\" data-end=\"1765\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCompensation of inductive and capacitive components\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1766\" data-end=\"1826\"\u003e\n\u003cp data-start=\"1768\" data-end=\"1826\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eBuilt-in active\/reactive energy meters (import\/export)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1827\" data-end=\"1877\"\u003e\n\u003cp data-start=\"1829\" data-end=\"1877\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of up to 31 harmonics of voltage and current\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1878\" data-end=\"1936\"\u003e\n\u003cp data-start=\"1880\" data-end=\"1936\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement of total harmonic distortion (THD)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1937\" data-end=\"2015\"\u003e\n\u003cp data-start=\"1939\" data-end=\"2015\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eBuilt-in reactive energy analyzer with log (20 data sets with 9999 min.)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2016\" data-end=\"2094\"\u003e\n\u003cp data-start=\"2018\" data-end=\"2094\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnection of single-, two-, and three-phase capacitors and shunt reactors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2095\" data-end=\"2139\"\u003e\n\u003cp data-start=\"2097\" data-end=\"2139\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eControl capability with generator supply\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2140\" data-end=\"2202\"\u003e\n\u003cp data-start=\"2142\" data-end=\"2202\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMax kvar per stage: 100 kVA, max for controller: 1200 kVA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2209\" data-end=\"2238\"\u003e\u003cstrong data-start=\"2213\" data-end=\"2238\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2240\" data-end=\"2641\"\u003e\n\u003cli data-start=\"2240\" data-end=\"2277\"\u003e\n\u003cp data-start=\"2242\" data-end=\"2277\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2242\" data-end=\"2262\"\u003eOperating voltage:\u003c\/strong\u003e 100-300 VAC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2278\" data-end=\"2359\"\u003e\n\u003cp data-start=\"2280\" data-end=\"2359\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2280\" data-end=\"2300\"\u003eMeasurement accuracy:\u003c\/strong\u003e current\/voltage ±0.5%, active power ±1%, reactive power ±2%.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2360\" data-end=\"2414\"\u003e\n\u003cp data-start=\"2362\" data-end=\"2414\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2362\" data-end=\"2399\"\u003eCurrent transformer range:\u003c\/strong\u003e 5\/5 ... 5000\/5\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2415\" data-end=\"2452\"\u003e\n\u003cp data-start=\"2417\" data-end=\"2452\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2417\" data-end=\"2431\"\u003eConnection:\u003c\/strong\u003e quick disconnect block\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2453\" data-end=\"2513\"\u003e\n\u003cp data-start=\"2455\" data-end=\"2513\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2455\" data-end=\"2472\"\u003eProtection rating:\u003c\/strong\u003e IP41 (front panel), IP20 (rear)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2514\" data-end=\"2559\"\u003e\n\u003cp data-start=\"2516\" data-end=\"2559\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2516\" data-end=\"2544\"\u003ePanel cutout dimensions:\u003c\/strong\u003e 140 × 140 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2560\" data-end=\"2641\"\u003e\n\u003cp data-start=\"2562\" data-end=\"2641\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2562\" data-end=\"2573\"\u003eMounting:\u003c\/strong\u003e reliable 4-point mounting (2 pressure + 2 screw terminals)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2648\" data-end=\"2674\"\u003e\u003cstrong data-start=\"2652\" data-end=\"2674\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay and indicator\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2676\" data-end=\"2864\"\u003e\n\u003cli data-start=\"2676\" data-end=\"2705\"\u003e\n\u003cp data-start=\"2678\" data-end=\"2705\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e2.9\" graphical LCD display\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2706\" data-end=\"2762\"\u003e\n\u003cp data-start=\"2708\" data-end=\"2762\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e17 LEDs for clear monitoring of operating parameters\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2763\" data-end=\"2794\"\u003e\n\u003cp data-start=\"2765\" data-end=\"2794\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of connected stages\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2795\" data-end=\"2864\"\u003e\n\u003cp data-start=\"2797\" data-end=\"2864\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of total and individual power, harmonics, and power factor\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2871\" data-end=\"3023\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2871\" data-end=\"2899\"\u003eThe controller is suitable for:\u003c\/strong\u003e\u003cbr data-start=\"2899\" data-end=\"2902\"\u003eIndustrial and civil facilities: factories, workshops, farms, hotels, gas stations, shopping centers, schools, hospitals, banks.\u003c\/font\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204696408392,"sku":"RGT-12(SVC)","price":258.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/ae4bcd478955332c8f4396aa87708907.png?v=1755800016","url":"https:\/\/pelek-de.com\/en\/products\/rgt-12svc-blindleistungsregler-12-stufen-tcr-mit-rs485-modbus-rtu","provider":"Deutschland Pelek","version":"1.0","type":"link"}