{"product_id":"rgt-12e-blindleistungsregler-12-stufen-tcr","title":"RGT-12E - Reactive power controller 12 steps +TCR","description":"\u003ch1 data-start=\"175\" data-end=\"262\"\u003e\u003cstrong data-start=\"177\" data-end=\"262\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eReactive power controller 12 steps + TCR with 2.9\" graphic LCD display (TENSE) - RGT-12E\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003cp data-start=\"264\" data-end=\"618\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe reactive power controller \u003cstrong data-start=\"290\" data-end=\"301\"\u003eRGT-12E\u003c\/strong\u003e from \u003cstrong data-start=\"317\" data-end=\"326\"\u003eTENSE\u003c\/strong\u003e is a fully automatic and highly precise controller for optimal control of compensation steps in power networks. With digital measurement acquisition, intelligent algorithms, and a graphical LCD display, it ensures a stable power factor, efficient reactive power control, and protection of compensation systems.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"625\" data-end=\"658\"\u003e\u003cstrong data-start=\"628\" data-end=\"658\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain features and functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 data-start=\"660\" data-end=\"708\"\u003e\u003cstrong data-start=\"664\" data-end=\"708\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic detection of compensation systems\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"709\" data-end=\"753\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller configures itself after switching on:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"754\" data-end=\"917\"\u003e\n\u003cli data-start=\"754\" data-end=\"823\"\u003e\n\u003cp data-start=\"756\" data-end=\"823\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIt automatically detects the size of the connected capacitor steps\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"824\" data-end=\"863\"\u003e\n\u003cp data-start=\"826\" data-end=\"863\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eit is also possible to enter parameters manually\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"864\" data-end=\"917\"\u003e\n\u003cp data-start=\"866\" data-end=\"917\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ethe system continuously checks the status of each step\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"919\" data-end=\"954\"\u003e\u003cstrong data-start=\"923\" data-end=\"954\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIntelligent switching control\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"955\" data-end=\"998\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller switches the steps on and off so that:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"999\" data-end=\"1283\"\u003e\n\u003cli data-start=\"999\" data-end=\"1063\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1063\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ea stable power factor with a minimal number of switchings is achieved\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1112\"\u003e\n\u003cp data-start=\"1066\" data-end=\"1112\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eindividual steps are evenly loaded\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1113\" data-end=\"1178\"\u003e\n\u003cp data-start=\"1115\" data-end=\"1178\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ecapacitors with the lowest residual charge are preferred\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1179\" data-end=\"1283\"\u003e\n\u003cp data-start=\"1181\" data-end=\"1283\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ethe status of each step is checked simultaneously (failures, power changes, removal and reactivation)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1285\" data-end=\"1333\"\u003e\u003cstrong data-start=\"1289\" data-end=\"1333\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTCR (Thyristor Switched Reactor) support\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"1334\" data-end=\"1418\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller enables compensation control with thyristor-switched reactors, which is ideal for:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1419\" data-end=\"1505\"\u003e\n\u003cli data-start=\"1419\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1421\" data-end=\"1442\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndustrial applications\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1443\" data-end=\"1468\"\u003e\n\u003cp data-start=\"1445\" data-end=\"1468\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDynamic compensation\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1469\" data-end=\"1505\"\u003e\n\u003cp data-start=\"1471\" data-end=\"1505\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSystems with frequent load changes\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1507\" data-end=\"1541\"\u003e\u003cstrong data-start=\"1511\" data-end=\"1541\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdvanced measurement and analysis\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"1542\" data-end=\"1796\"\u003e\n\u003cli data-start=\"1542\" data-end=\"1606\"\u003e\n\u003cp data-start=\"1544\" data-end=\"1606\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement of harmonic voltages and currents up to the \u003cstrong data-start=\"1586\" data-end=\"1604\"\u003e31st harmonic\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1654\"\u003e\n\u003cp data-start=\"1609\" data-end=\"1654\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMonitoring of total energy (import\/export)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1655\" data-end=\"1695\"\u003e\n\u003cp data-start=\"1657\" data-end=\"1695\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement of THD-V and THD-I for each phase\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1696\" data-end=\"1796\"\u003e\n\u003cp data-start=\"1698\" data-end=\"1796\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGeneration of power analyses (\u003cstrong data-start=\"1721\" data-end=\"1746\"\u003e20 samples from 9999 min\u003c\/strong\u003e) - very useful for planning compensation systemsFlexible\u003c\/font\u003e\u003cstrong data-start=\"1802\" data-end=\"1845\" style=\"color: rgb(25, 32, 39); font-family: inherit; font-size: 18px;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWiring of compensation elements\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1846\" data-end=\"1864\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplications:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1865\" data-end=\"1977\"\u003e\n\u003cli data-start=\"1865\" data-end=\"1895\"\u003e\n\u003cp data-start=\"1867\" data-end=\"1895\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSingle-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1896\" data-end=\"1925\"\u003e\n\u003cp data-start=\"1898\" data-end=\"1925\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTwo-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1926\" data-end=\"1954\"\u003e\n\u003cp data-start=\"1928\" data-end=\"1954\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThree-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"1977\"\u003e\n\u003cp data-start=\"1957\" data-end=\"1977\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eShunt reactors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1979\" data-end=\"2013\"\u003e\u003cstrong data-start=\"1983\" data-end=\"2013\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdjustable time functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"2014\" data-end=\"2029\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCan be set:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"2030\" data-end=\"2143\"\u003e\n\u003cli data-start=\"2030\" data-end=\"2045\"\u003e\n\u003cp data-start=\"2032\" data-end=\"2045\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSwitch-on time\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2046\" data-end=\"2063\"\u003e\n\u003cp data-start=\"2048\" data-end=\"2063\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDischarge time\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2064\" data-end=\"2143\"\u003e\n\u003cp data-start=\"2066\" data-end=\"2143\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSettling time\u003cbr data-start=\"2080\" data-end=\"2083\"\u003eThis allows precise adjustment of the control to the type of operation.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"2145\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2149\" data-end=\"2170\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGenerator functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"2171\" data-end=\"2186\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller features:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"2187\" data-end=\"2264\"\u003e\n\u003cli data-start=\"2187\" data-end=\"2218\"\u003e\n\u003cp data-start=\"2189\" data-end=\"2218\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eControl input for the generator\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2219\" data-end=\"2264\"\u003e\n\u003cp data-start=\"2221\" data-end=\"2264\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGenerator supply compensation function\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2271\" data-end=\"2316\"\u003e\u003cstrong data-start=\"2274\" data-end=\"2316\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical features (summary)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\u003c\/p\u003e\u003cul data-start=\"2318\" data-end=\"2680\"\u003e\n\u003cli data-start=\"2318\" data-end=\"2356\"\u003e\n\u003cp data-start=\"2320\" data-end=\"2356\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e12 relay compensation outputs\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2357\" data-end=\"2372\"\u003e\n\u003cp data-start=\"2359\" data-end=\"2372\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTCR support\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2373\" data-end=\"2402\"\u003e\n\u003cp data-start=\"2375\" data-end=\"2402\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e2.9\" graphical LCD display\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2403\" data-end=\"2433\"\u003e\n\u003cp data-start=\"2405\" data-end=\"2433\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic step detection\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2434\" data-end=\"2472\"\u003e\n\u003cp data-start=\"2436\" data-end=\"2472\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHarmonic measurement up to the 31st order\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2473\" data-end=\"2510\"\u003e\n\u003cp data-start=\"2475\" data-end=\"2510\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEnergy statistics and history\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2511\" data-end=\"2528\"\u003e\n\u003cp data-start=\"2513\" data-end=\"2528\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTHD-V \/ THD-I\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2529\" data-end=\"2589\"\u003e\n\u003cp data-start=\"2531\" data-end=\"2589\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSupport for single-phase, two-phase, and three-phase steps\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2590\" data-end=\"2641\"\u003e\n\u003cp data-start=\"2592\" data-end=\"2641\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProgrammable off, on, and discharge time\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2642\" data-end=\"2680\"\u003e\n\u003cp data-start=\"2644\" data-end=\"2680\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eStep disturbance protection\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204696080712,"sku":"RGT-12E","price":216.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/a1a8c8ce294759ea0cac4554bed17012.png?v=1755799996","url":"https:\/\/pelek-de.com\/en\/products\/rgt-12e-blindleistungsregler-12-stufen-tcr","provider":"Deutschland Pelek","version":"1.0","type":"link"}