{"product_id":"regler-fur-einphasige-pumpen-bis-zu-30a","title":"Regulator for single-phase pumps up to 30A","description":"\u003cdiv\u003e\n\u003ch1 data-start=\"124\" data-end=\"211\"\u003e\u003cstrong data-start=\"126\" data-end=\"211\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eTENSE MDK-02 single-phase submersible motor pump control, 140-280 V AC, 60 A\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"213\" data-end=\"236\"\u003e\u003cstrong data-start=\"216\" data-end=\"234\"\u003e\u003cfont style=\"font-size: 16px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"237\" data-end=\"547\"\u003eThe TENSE MDK-02 control unit is designed for the \u003cstrong data-start=\"273\" data-end=\"312\"\u003eprotection and control of submersible pumps\u003c\/strong\u003e for boreholes and wells.\u003cbr data-start=\"330\" data-end=\"333\"\u003e\nIt provides protection against voltage and current spikes, water shortage, and pump overload.\u003cbr data-start=\"426\" data-end=\"429\"\u003e\nIntegrated functions also enable \u003cstrong data-start=\"460\" data-end=\"546\"\u003emonitoring of tank fill level, setting of time delay, and control of inrush current\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"554\" data-end=\"579\"\u003e\u003cstrong data-start=\"557\" data-end=\"579\"\u003e\u003cfont style=\"font-size: 16px;\"\u003eKey features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"580\" data-end=\"1125\"\u003e\n\u003cli data-start=\"580\" data-end=\"626\"\u003e\n\u003cp data-start=\"582\" data-end=\"626\"\u003eSingle-phase power supply, range: 140-280 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"627\" data-end=\"647\"\u003e\n\u003cp data-start=\"629\" data-end=\"647\"\u003eMax. current: 60 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"648\" data-end=\"691\"\u003e\n\u003cp data-start=\"650\" data-end=\"691\"\u003eMicroprocessor control with LED display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"809\"\u003e\n\u003cp data-start=\"694\" data-end=\"712\"\u003eProtection functions:\u003c\/p\u003e\n\u003cul data-start=\"715\" data-end=\"809\"\u003e\n\u003cli data-start=\"715\" data-end=\"736\"\u003e\n\u003cp data-start=\"717\" data-end=\"736\"\u003eOvervoltage\/undervoltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"739\" data-end=\"762\"\u003e\n\u003cp data-start=\"741\" data-end=\"762\"\u003eOvercurrent\/undercurrent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"765\" data-end=\"809\"\u003e\n\u003cp data-start=\"767\" data-end=\"809\"\u003eWell\/tank water level control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"810\" data-end=\"954\"\u003e\n\u003cp data-start=\"812\" data-end=\"954\"\u003eOperating parameter settings: P1-P10 (e.g., maximum\/minimum voltage, current, response delay, start interval, automatic reset time)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"955\" data-end=\"987\"\u003e\n\u003cp data-start=\"957\" data-end=\"987\"\u003eOperating modes: START \/ STOP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"988\" data-end=\"1072\"\u003e\n\u003cp data-start=\"990\" data-end=\"1072\"\u003eBuilt-in \u003cstrong data-start=\"1000\" data-end=\"1033\"\u003epump delay timer\u003c\/strong\u003e to extend pump life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1073\" data-end=\"1125\"\u003e\n\u003cp data-start=\"1075\" data-end=\"1125\"\u003ePump status display via LED indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1132\" data-end=\"1158\"\u003e\u003cstrong data-start=\"1135\" data-end=\"1158\"\u003e\u003cfont style=\"font-size: 16px;\"\u003eTechnical parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1159\" data-end=\"1534\"\u003e\n\u003cli data-start=\"1159\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1161\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1161\" data-end=\"1181\"\u003eOperating voltage:\u003c\/strong\u003e 140-280 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1221\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1221\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1213\"\u003eFrequency:\u003c\/strong\u003e 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1222\" data-end=\"1253\"\u003e\n\u003cp data-start=\"1224\" data-end=\"1253\"\u003e\u003cstrong data-start=\"1224\" data-end=\"1242\"\u003eCurrent range:\u003c\/strong\u003e 0,5-60 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1254\" data-end=\"1285\"\u003e\n\u003cp data-start=\"1256\" data-end=\"1285\"\u003e\u003cstrong data-start=\"1256\" data-end=\"1277\"\u003ePower consumption:\u003c\/strong\u003e \u0026lt; 4 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1286\" data-end=\"1324\"\u003e\n\u003cp data-start=\"1288\" data-end=\"1324\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1314\"\u003eLiquid sensitivity:\u003c\/strong\u003e \u0026lt; 50 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1325\" data-end=\"1352\"\u003e\n\u003cp data-start=\"1327\" data-end=\"1352\"\u003e\u003cstrong data-start=\"1327\" data-end=\"1345\"\u003eProtection class:\u003c\/strong\u003e IP40\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1353\" data-end=\"1394\"\u003e\n\u003cp data-start=\"1355\" data-end=\"1394\"\u003e\u003cstrong data-start=\"1355\" data-end=\"1376\"\u003eOperating temperature:\u003c\/strong\u003e -5 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1430\"\u003e\n\u003cp data-start=\"1397\" data-end=\"1430\"\u003e\u003cstrong data-start=\"1397\" data-end=\"1420\"\u003eMax. cable cross-section:\u003c\/strong\u003e 1.5 mm²\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1431\" data-end=\"1467\"\u003e\n\u003cp data-start=\"1433\" data-end=\"1467\"\u003e\u003cstrong data-start=\"1433\" data-end=\"1454\"\u003eInstallation opening:\u003c\/strong\u003e 91 × 91 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1468\" data-end=\"1510\"\u003e\n\u003cp data-start=\"1470\" data-end=\"1510\"\u003e\u003cstrong data-start=\"1470\" data-end=\"1499\"\u003eInstallation height:\u003c\/strong\u003e \u0026lt; 2000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1511\" data-end=\"1534\"\u003e\n\u003cp data-start=\"1513\" data-end=\"1534\"\u003e\u003cstrong data-start=\"1513\" data-end=\"1526\"\u003eWeight:\u003c\/strong\u003e 325 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1541\" data-end=\"1555\"\u003e\u003cstrong data-start=\"1544\" data-end=\"1555\"\u003e\u003cfont style=\"font-size: 16px;\"\u003eApplication\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1556\" data-end=\"1739\"\u003e\n\u003cli data-start=\"1556\" data-end=\"1623\"\u003e\n\u003cp data-start=\"1558\" data-end=\"1623\"\u003eProtection of submersible pumps against \u003cstrong data-start=\"1590\" data-end=\"1621\"\u003edry running and overload\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1624\" data-end=\"1671\"\u003e\n\u003cp data-start=\"1626\" data-end=\"1671\"\u003eWater level control in tanks and wells\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1739\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1739\"\u003eMonitoring and safe operation of household and industrial pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1746\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1749\" data-end=\"1772\"\u003e\u003cfont style=\"font-size: 16px;\"\u003eImportant notes\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1773\" data-end=\"2136\"\u003e\n\u003cli data-start=\"1773\" data-end=\"1865\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1865\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1835\"\u003eElectrodes \/ water level sensors are not included\u003c\/strong\u003e - must be ordered separately\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1866\" data-end=\"1933\"\u003e\n\u003cp data-start=\"1868\" data-end=\"1933\"\u003eThe control unit must be connected according to the \u003cstrong data-start=\"1902\" data-end=\"1931\"\u003emanufacturer's wiring diagram\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1934\" data-end=\"1976\"\u003e\n\u003cp data-start=\"1936\" data-end=\"1976\"\u003eThe liquid must not be flammable or explosive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1977\" data-end=\"2014\"\u003e\n\u003cp data-start=\"1979\" data-end=\"2014\"\u003eInstallation temperature must be \u0026gt; 0 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2015\" data-end=\"2045\"\u003e\n\u003cp data-start=\"2017\" data-end=\"2045\"\u003ePump must be grounded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2046\" data-end=\"2136\"\u003e\n\u003cp data-start=\"2048\" data-end=\"2136\"\u003eThe use of two level sensors requires the correct connection of the upper and middle sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51205740921160,"sku":"MDK-02","price":83.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/7e59b54c85045a578e7f7c49529b5d8b.png?v=1755806807","url":"https:\/\/pelek-de.com\/en\/products\/regler-fur-einphasige-pumpen-bis-zu-30a","provider":"Deutschland Pelek","version":"1.0","type":"link"}