{"product_id":"pumpenschutz-gegen-trockenlauf-din-tauchpumpensteuerung","title":"Pump protection against dry running, DIN submersible pump control","description":"\u003ch1 data-start=\"99\" data-end=\"186\"\u003e\u003cstrong data-start=\"101\" data-end=\"186\"\u003e\u003cfont style=\"font-size: 16px;\"\u003ePump controller for TENSE submersible and borehole pumps, 1-30 A, 200-460 V AC\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"188\" data-end=\"211\"\u003e\u003cstrong data-start=\"191\" data-end=\"209\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"212\" data-end=\"466\"\u003eThe TENSE pump controller is designed for \u003cstrong data-start=\"257\" data-end=\"305\"\u003econtrol and protection of submersible pumps and motors\u003c\/strong\u003e in wells, tanks, and water reservoirs.\u003cbr data-start=\"347\" data-end=\"350\"\u003e\nIt ensures safe operation and protects devices from dry running, over- and undervoltage, as well as current or voltage imbalance.\u003c\/p\u003e\n\u003ch2 data-start=\"473\" data-end=\"498\"\u003e\u003cstrong data-start=\"476\" data-end=\"498\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"499\" data-end=\"992\"\u003e\n\u003cli data-start=\"499\" data-end=\"556\"\u003e\n\u003cp data-start=\"501\" data-end=\"556\"\u003ePump control and protection against adverse conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"557\" data-end=\"607\"\u003e\n\u003cp data-start=\"559\" data-end=\"607\"\u003eBuilt-in \u003cstrong data-start=\"569\" data-end=\"605\"\u003ecurrent transformers and contactor\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"608\" data-end=\"711\"\u003e\n\u003cp data-start=\"610\" data-end=\"628\"\u003eProtection functions:\u003c\/p\u003e\n\u003cul data-start=\"631\" data-end=\"711\"\u003e\n\u003cli data-start=\"631\" data-end=\"652\"\u003e\n\u003cp data-start=\"633\" data-end=\"652\"\u003eOvervoltage\/undervoltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"655\" data-end=\"677\"\u003e\n\u003cp data-start=\"657\" data-end=\"677\"\u003eOvercurrent\/undervoltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"680\" data-end=\"711\"\u003e\n\u003cp data-start=\"682\" data-end=\"711\"\u003eCurrent and voltage imbalance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"712\" data-end=\"747\"\u003e\n\u003cp data-start=\"714\" data-end=\"747\"\u003eFault timeout setting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"748\" data-end=\"787\"\u003e\n\u003cp data-start=\"750\" data-end=\"787\"\u003eAutomatic reset of timer and counter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"788\" data-end=\"863\"\u003e\n\u003cp data-start=\"790\" data-end=\"863\"\u003eSupports \u003cstrong data-start=\"798\" data-end=\"861\"\u003emanual, semi-automatic, and automatic reset modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"864\" data-end=\"910\"\u003e\n\u003cp data-start=\"866\" data-end=\"910\"\u003eSetting of failure time and time multiplier\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"911\" data-end=\"941\"\u003e\n\u003cp data-start=\"913\" data-end=\"941\"\u003ePhase sequence control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"942\" data-end=\"992\"\u003e\n\u003cp data-start=\"944\" data-end=\"992\"\u003eMonitoring total operating time and number of switches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"999\" data-end=\"1025\"\u003e\u003cstrong data-start=\"1002\" data-end=\"1025\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1026\" data-end=\"1483\"\u003e\n\u003cli data-start=\"1026\" data-end=\"1068\"\u003e\n\u003cp data-start=\"1028\" data-end=\"1068\"\u003e\u003cstrong data-start=\"1028\" data-end=\"1053\"\u003eOperating voltage (Un):\u003c\/strong\u003e 100-240 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1069\" data-end=\"1095\"\u003e\n\u003cp data-start=\"1071\" data-end=\"1095\"\u003e\u003cstrong data-start=\"1071\" data-end=\"1084\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1096\" data-end=\"1125\"\u003e\n\u003cp data-start=\"1098\" data-end=\"1125\"\u003e\u003cstrong data-start=\"1098\" data-end=\"1116\"\u003eCurrent range:\u003c\/strong\u003e 1-30 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1126\" data-end=\"1169\"\u003e\n\u003cp data-start=\"1128\" data-end=\"1169\"\u003e\u003cstrong data-start=\"1128\" data-end=\"1140\"\u003eDisplay:\u003c\/strong\u003e 3-digit LED with 8 indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1170\" data-end=\"1207\"\u003e\n\u003cp data-start=\"1172\" data-end=\"1207\"\u003e\u003cstrong data-start=\"1172\" data-end=\"1198\"\u003eLiquid sensitivity:\u003c\/strong\u003e \u0026lt;50 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1208\" data-end=\"1238\"\u003e\n\u003cp data-start=\"1210\" data-end=\"1238\"\u003e\u003cstrong data-start=\"1210\" data-end=\"1229\"\u003eOperating power:\u003c\/strong\u003e \u0026lt;10 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1239\" data-end=\"1281\"\u003e\n\u003cp data-start=\"1241\" data-end=\"1281\"\u003e\u003cstrong data-start=\"1241\" data-end=\"1262\"\u003eOperating temperature:\u003c\/strong\u003e -20 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1282\" data-end=\"1348\"\u003e\n\u003cp data-start=\"1284\" data-end=\"1348\"\u003e\u003cstrong data-start=\"1284\" data-end=\"1302\"\u003eCable diameter:\u003c\/strong\u003e 2.5 mm² (outputs) \/ 6 mm² (power inputs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1349\" data-end=\"1398\"\u003e\n\u003cp data-start=\"1351\" data-end=\"1398\"\u003e\u003cstrong data-start=\"1351\" data-end=\"1364\"\u003eContacts:\u003c\/strong\u003e 3 A \/ 250 V AC (resistive load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1399\" data-end=\"1424\"\u003e\n\u003cp data-start=\"1401\" data-end=\"1424\"\u003e\u003cstrong data-start=\"1401\" data-end=\"1412\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1425\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1427\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1427\" data-end=\"1440\"\u003eWeight:\u003c\/strong\u003e 380 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1483\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1483\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1471\"\u003eAltitude:\u003c\/strong\u003e up to 2000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1490\" data-end=\"1504\"\u003e\u003cstrong data-start=\"1493\" data-end=\"1504\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1505\" data-end=\"1705\"\u003e\n\u003cli data-start=\"1505\" data-end=\"1561\"\u003e\n\u003cp data-start=\"1507\" data-end=\"1561\"\u003eIdeal for \u003cstrong data-start=\"1519\" data-end=\"1559\"\u003eprotecting pumps from dry running\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1562\" data-end=\"1630\"\u003e\n\u003cp data-start=\"1564\" data-end=\"1630\"\u003eOverload and overvoltage protection in residential and industrial systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1631\" data-end=\"1705\"\u003e\n\u003cp data-start=\"1633\" data-end=\"1705\"\u003eControl of submersible and borehole pumps in tanks, containers, and wells\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1712\" data-end=\"1738\"\u003e\u003cstrong data-start=\"1715\" data-end=\"1738\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eImportant notes\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1739\" data-end=\"1899\"\u003e\n\u003cli data-start=\"1739\" data-end=\"1831\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1831\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1801\"\u003eElectrodes \/ water level sensors are not included\u003c\/strong\u003e - must be ordered separately\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1832\" data-end=\"1899\"\u003e\n\u003cp data-start=\"1834\" data-end=\"1899\"\u003eRecommended 2-A circuit breaker for protection of inlet and outlet channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51205742854472,"sku":"TDK-30","price":104.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/395faea6dc3a503f2c31184a1d540344.png?v=1755806829","url":"https:\/\/pelek-de.com\/en\/products\/pumpenschutz-gegen-trockenlauf-din-tauchpumpensteuerung","provider":"Deutschland Pelek","version":"1.0","type":"link"}