{"product_id":"phasenregelungsrelais-fkv-03f","title":"Phase control relay FKV-03F","description":"\u003ch2 data-start=\"73\" data-end=\"123\"\u003e\u003cstrong data-start=\"76\" data-end=\"123\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eFKV-03F - Phase monitoring relay, TENSE\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"125\" data-end=\"147\"\u003e\u003cstrong data-start=\"129\" data-end=\"147\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"148\" data-end=\"361\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe FKV-03F relay is used to protect three-phase electric motors from incorrect phase sequence, phase failure, and voltage asymmetry (fixed at 40%). The device includes a neutral conductor and a clear LED display for status and errors.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"363\" data-end=\"386\"\u003e\u003cstrong data-start=\"367\" data-end=\"386\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFunction and operation\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"387\" data-end=\"702\"\u003e\n\u003cli data-start=\"387\" data-end=\"440\"\u003e\n\u003cp data-start=\"389\" data-end=\"440\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"389\" data-end=\"409\"\u003eNormal operation:\u003c\/strong\u003e LED OUT lights up, relay activated.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"441\" data-end=\"501\"\u003e\n\u003cp data-start=\"443\" data-end=\"501\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"443\" data-end=\"463\"\u003eAsymmetry error:\u003c\/strong\u003e LED ERR off, relay deactivated.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"502\" data-end=\"589\"\u003e\n\u003cp data-start=\"504\" data-end=\"589\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"504\" data-end=\"528\"\u003eIncorrect phase sequence:\u003c\/strong\u003e error indicator lights up, LED OUT off, relay deactivated.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"590\" data-end=\"702\"\u003e\n\u003cp data-start=\"592\" data-end=\"607\"\u003e\u003cstrong data-start=\"592\" data-end=\"605\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eContacts:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"610\" data-end=\"702\"\u003e\n\u003cli data-start=\"610\" data-end=\"652\"\u003e\n\u003cp data-start=\"612\" data-end=\"652\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelay activated: 2 (COM) and 3 (NO) connected.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"655\" data-end=\"702\"\u003e\n\u003cp data-start=\"657\" data-end=\"702\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelay deactivated: 2 (COM) and 3 (NO) connected\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"704\" data-end=\"727\"\u003e\u003cstrong data-start=\"708\" data-end=\"727\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"728\" data-end=\"1035\"\u003e\n\u003cli data-start=\"728\" data-end=\"774\"\u003e\n\u003cp data-start=\"730\" data-end=\"774\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating voltage: 3×380 V AC + neutral conductor\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"775\" data-end=\"798\"\u003e\n\u003cp data-start=\"777\" data-end=\"798\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFrequency: 50\/60 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"799\" data-end=\"826\"\u003e\n\u003cp data-start=\"801\" data-end=\"826\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePower consumption: \u0026lt;6 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"827\" data-end=\"852\"\u003e\n\u003cp data-start=\"829\" data-end=\"852\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAsymmetry: fixed 40%\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"897\"\u003e\n\u003cp data-start=\"855\" data-end=\"897\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eContact: 5 A \/ 250 V AC (resistive load)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"898\" data-end=\"923\"\u003e\n\u003cp data-start=\"900\" data-end=\"923\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLED display: 3 diodes\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"924\" data-end=\"945\"\u003e\n\u003cp data-start=\"926\" data-end=\"945\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMounting: DIN rail\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"946\" data-end=\"984\"\u003e\n\u003cp data-start=\"948\" data-end=\"984\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating temperature: -20 °C to +55 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"985\" data-end=\"1014\"\u003e\n\u003cp data-start=\"987\" data-end=\"1014\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCable diameter: up to 2.5 mm²\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1015\" data-end=\"1035\"\u003e\n\u003cp data-start=\"1017\" data-end=\"1035\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWeight: \u0026lt;150 g\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1037\" data-end=\"1052\"\u003e\u003cstrong data-start=\"1041\" data-end=\"1052\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1053\" data-end=\"1159\"\u003e\n\u003cli data-start=\"1053\" data-end=\"1080\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1080\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThree-phase electric motors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1081\" data-end=\"1113\"\u003e\n\u003cp data-start=\"1083\" data-end=\"1113\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndustrial machines and pumps\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1114\" data-end=\"1159\"\u003e\n\u003cp data-start=\"1116\" data-end=\"1159\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDevices sensitive to the quality of the power supply network\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204697981256,"sku":"FKV-03F","price":21.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/5cb39fecda74296372472f84483849e7.png?v=1755800042","url":"https:\/\/pelek-de.com\/en\/products\/phasenregelungsrelais-fkv-03f","provider":"Deutschland Pelek","version":"1.0","type":"link"}