{"product_id":"onka-stromwandler-stromwandler-1200-5a-100mm-class-0-5s-10va-tk10012005307-80011773","title":"ONKA Current Transformer - CURRENT TRANSFORMER 1200\/5A, 100MM, CLASS 0.5S, 10VA (TK10012005307 \/ 80011773)","description":"\u003cp\u003e\u003cstrong\u003e\u003cfont style=\"\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eSlip-on measuring transformer for primary rated currents of 1200 A, secondary current 5 A, rated power 10 VA, available in accuracy class 0.5S, ONKA.\u003c\/font\u003e\u003cbr\u003e\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"143\" data-end=\"435\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe ONKA TK10012005307 is a highly precise \u003cstrong data-start=\"179\" data-end=\"213\"\u003eslip-on current transformer\u003c\/strong\u003e for indirect AC measurement in \u003cstrong data-start=\"260\" data-end=\"302\"\u003eelectrical installations and switch cabinets\u003c\/strong\u003e. It converts a high primary current into a standard secondary current of 5 A, enabling safe connection to measurement and protection systems.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"442\" data-end=\"470\"\u003e\u003cstrong data-start=\"445\" data-end=\"470\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 data-start=\"472\" data-end=\"498\"\u003e\u003cstrong data-start=\"476\" data-end=\"498\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eBasic parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"499\" data-end=\"737\"\u003e\n\u003cli data-start=\"499\" data-end=\"539\"\u003e\n\u003cp data-start=\"501\" data-end=\"539\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"501\" data-end=\"530\"\u003ePrimary rated current:\u003c\/strong\u003e 1200 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"540\" data-end=\"569\"\u003e\n\u003cp data-start=\"542\" data-end=\"569\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"542\" data-end=\"563\"\u003eSecondary current:\u003c\/strong\u003e 5 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"570\" data-end=\"627\"\u003e\n\u003cp data-start=\"572\" data-end=\"627\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"572\" data-end=\"618\"\u003eBus diameter\/inner diameter of mounting:\u003c\/strong\u003e 100 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"628\" data-end=\"658\"\u003e\n\u003cp data-start=\"630\" data-end=\"658\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"630\" data-end=\"650\"\u003eRated power:\u003c\/strong\u003e 10 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"659\" data-end=\"737\"\u003e\n\u003cp data-start=\"661\" data-end=\"737\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"661\" data-end=\"681\"\u003eAccuracy class:\u003c\/strong\u003e 0.5S - suitable for precise load measurement and monitoring\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"739\" data-end=\"756\"\u003e\u003cstrong data-start=\"743\" data-end=\"756\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eInstallation:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"757\" data-end=\"915\"\u003e\n\u003cli data-start=\"757\" data-end=\"799\"\u003e\n\u003cp data-start=\"759\" data-end=\"799\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"759\" data-end=\"775\"\u003eMounting type:\u003c\/strong\u003e plug-in transformer\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"800\" data-end=\"839\"\u003e\n\u003cp data-start=\"802\" data-end=\"839\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"802\" data-end=\"821\"\u003eMounting feet:\u003c\/strong\u003e included\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"840\" data-end=\"915\"\u003e\n\u003cp data-start=\"842\" data-end=\"915\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"842\" data-end=\"863\"\u003eEasy installation:\u003c\/strong\u003e plug-in design without interrupting the main circuit\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"922\" data-end=\"934\"\u003e\u003cstrong data-start=\"925\" data-end=\"934\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDescription\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp data-start=\"936\" data-end=\"1044\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe transformer converts a high primary current (1200 A) into a standardized secondary current of 5 A. This enables:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1046\" data-end=\"1228\"\u003e\n\u003cli data-start=\"1046\" data-end=\"1079\"\u003e\n\u003cp data-start=\"1048\" data-end=\"1079\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnection of meters and ammeters (1.5 to 2.5 amperes).\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1080\" data-end=\"1115\"\u003e\n\u003cp data-start=\"1082\" data-end=\"1115\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIntegration into protection systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1116\" data-end=\"1150\"\u003e\n\u003cp data-start=\"1118\" data-end=\"1150\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLoad monitoring and control\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1151\" data-end=\"1228\"\u003e\n\u003cp data-start=\"1153\" data-end=\"1228\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEasy installation in switchboards thanks to a standard 100 mm busbar\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1230\" data-end=\"1357\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe compact dimensions and robust design ensure reliability and long service life even in industrial or commercial applications.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"1364\" data-end=\"1377\"\u003e\u003cstrong data-start=\"1367\" data-end=\"1377\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdvantages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cul data-start=\"1379\" data-end=\"1708\"\u003e\n\u003cli data-start=\"1379\" data-end=\"1438\"\u003e\n\u003cp data-start=\"1381\" data-end=\"1438\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1381\" data-end=\"1409\"\u003ePrimary current up to 1200 A\u003c\/strong\u003e - suitable for high loads\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1439\" data-end=\"1512\"\u003e\n\u003cp data-start=\"1441\" data-end=\"1512\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1441\" data-end=\"1465\"\u003eSecondary current 5 A\u003c\/strong\u003e - compatible with most measuring devices\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1570\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1570\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1539\"\u003eAccuracy class 0.5S\u003c\/strong\u003e - reliable and precise measurement\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1571\" data-end=\"1636\"\u003e\n\u003cp data-start=\"1573\" data-end=\"1636\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1573\" data-end=\"1594\"\u003eCompact housing\u003c\/strong\u003e - easy installation on 100 mm busbar\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1637\" data-end=\"1708\"\u003e\n\u003cp data-start=\"1639\" data-end=\"1708\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1639\" data-end=\"1664\"\u003eRated power 10 VA\u003c\/strong\u003e - sufficient for most measurement systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1715\" data-end=\"1729\"\u003e\u003cstrong data-start=\"1718\" data-end=\"1729\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\u003c\/p\u003e\u003cul data-start=\"1731\" data-end=\"1935\"\u003e\n\u003cli data-start=\"1731\" data-end=\"1766\"\u003e\n\u003cp data-start=\"1733\" data-end=\"1766\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndustrial and commercial switchgear\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1767\" data-end=\"1817\"\u003e\n\u003cp data-start=\"1769\" data-end=\"1817\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eElectricity measurement and load monitoring systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1818\" data-end=\"1872\"\u003e\n\u003cp data-start=\"1820\" data-end=\"1872\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnection of meters, ammeters, and protective devices\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1873\" data-end=\"1935\"\u003e\n\u003cp data-start=\"1875\" data-end=\"1935\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCurrent monitoring in networks with primary currents up to 1200 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ONKA","offers":[{"title":"Default Title","offer_id":51205668077896,"sku":"80011773","price":39.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/2d1953b4a3672e421de1883311d6b455.jpg?v=1755805562","url":"https:\/\/pelek-de.com\/en\/products\/onka-stromwandler-stromwandler-1200-5a-100mm-class-0-5s-10va-tk10012005307-80011773","provider":"Deutschland Pelek","version":"1.0","type":"link"}