{"product_id":"onka-stromwandler-stromwandler-1000-5a-80mm-class-0-5s-15va-80011769-tk8010005309","title":"ONKA Current Transformer - CURRENT TRANSFORMER 1000\/5A, 80MM, CLASS 0.5S, 15VA (80011769 \/ TK8010005309)","description":"\u003cp\u003e\u003cstrong\u003e\u003cfont style=\"font-size: 18px;\"\u003eClip-on current transformer for primary rated currents of 1000 A, secondary current 5 A, rated power 15 VA, available in accuracy class 0.5S, ONKA.\u003c\/font\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"153\" data-end=\"485\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe ONKA TK8010005309 is a highly precise \u003cstrong data-start=\"188\" data-end=\"224\" style=\"\"\u003eclip-on current transformer\u003c\/strong\u003e for indirect measurement of sinusoidal alternating current in \u003cstrong data-start=\"282\" data-end=\"336\" style=\"\"\u003edistribution systems and electrical switchgear\u003c\/strong\u003e. It enables the safe conversion of \u003cstrong data-start=\"381\" data-end=\"391\" style=\"\"\u003e1000 A\u003c\/strong\u003e primary current into a standard secondary current \u003cstrong data-start=\"423\" data-end=\"430\" style=\"\"\u003eof 5 A\u003c\/strong\u003e, compatible with most measuring and control devices.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"492\" data-end=\"520\"\u003e\u003cstrong data-start=\"495\" data-end=\"520\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 data-start=\"522\" data-end=\"548\"\u003e\u003cstrong data-start=\"526\" data-end=\"548\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eBasic parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"549\" data-end=\"764\"\u003e\n\u003cli data-start=\"549\" data-end=\"589\"\u003e\n\u003cp data-start=\"551\" data-end=\"589\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"551\" data-end=\"580\"\u003ePrimary rated current:\u003c\/strong\u003e 1000 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"590\" data-end=\"619\"\u003e\n\u003cp data-start=\"592\" data-end=\"619\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"592\" data-end=\"613\"\u003eSecondary current:\u003c\/strong\u003e 5 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"620\" data-end=\"670\"\u003e\n\u003cp data-start=\"622\" data-end=\"670\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"622\" data-end=\"662\"\u003eInner diameter \/ busbar mounting:\u003c\/strong\u003e 80 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"671\" data-end=\"701\"\u003e\n\u003cp data-start=\"673\" data-end=\"701\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"673\" data-end=\"693\"\u003eRated power:\u003c\/strong\u003e 15 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"702\" data-end=\"764\"\u003e\n\u003cp data-start=\"704\" data-end=\"764\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"704\" data-end=\"724\"\u003eAccuracy class:\u003c\/strong\u003e 0.5S - for reliable and accurate measurements\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"766\" data-end=\"783\"\u003e\u003cstrong data-start=\"770\" data-end=\"783\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eInstallation\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"784\" data-end=\"945\"\u003e\n\u003cli data-start=\"784\" data-end=\"826\"\u003e\n\u003cp data-start=\"786\" data-end=\"826\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"786\" data-end=\"802\"\u003eMounting type:\u003c\/strong\u003e plug-in transformer\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"827\" data-end=\"866\"\u003e\n\u003cp data-start=\"829\" data-end=\"866\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"829\" data-end=\"848\"\u003eMounting feet:\u003c\/strong\u003e included\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"867\" data-end=\"945\"\u003e\n\u003cp data-start=\"869\" data-end=\"945\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"869\" data-end=\"890\"\u003eEasy installation:\u003c\/strong\u003e snap-on design, no interruption of the main circuit\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"952\" data-end=\"964\"\u003e\u003cstrong data-start=\"955\" data-end=\"964\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDescription\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp data-start=\"966\" data-end=\"1081\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe transformer converts a high primary current (1000 A) into a standard output of 5 A and allows safe connection to:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1083\" data-end=\"1181\"\u003e\n\u003cli data-start=\"1083\" data-end=\"1108\"\u003e\n\u003cp data-start=\"1085\" data-end=\"1108\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeters and current measuring devices\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1109\" data-end=\"1149\"\u003e\n\u003cp data-start=\"1111\" data-end=\"1149\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eControl and monitoring systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1150\" data-end=\"1181\"\u003e\n\u003cp data-start=\"1152\" data-end=\"1181\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtection and measurement circuits\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1183\" data-end=\"1382\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWith an accuracy class of 0.5S, it provides stable and accurate data even at partial loads. Its compact size and standard output make it a versatile choice for private, commercial, and industrial applications.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"1389\" data-end=\"1402\"\u003e\u003cstrong data-start=\"1392\" data-end=\"1402\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdvantages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cul data-start=\"1404\" data-end=\"1733\"\u003e\n\u003cli data-start=\"1404\" data-end=\"1469\"\u003e\n\u003cp data-start=\"1406\" data-end=\"1469\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1406\" data-end=\"1434\"\u003ePrimary current up to 1000 A\u003c\/strong\u003e - suitable for high-current circuits\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1470\" data-end=\"1543\"\u003e\n\u003cp data-start=\"1472\" data-end=\"1543\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1472\" data-end=\"1496\"\u003eSecondary current 5 A\u003c\/strong\u003e - compatible with most measuring devices\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1544\" data-end=\"1603\"\u003e\n\u003cp data-start=\"1546\" data-end=\"1603\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1546\" data-end=\"1570\"\u003eAccuracy class 0.5S\u003c\/strong\u003e - reliable and stable measurements\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1604\" data-end=\"1659\"\u003e\n\u003cp data-start=\"1606\" data-end=\"1659\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1606\" data-end=\"1627\"\u003eCompact size\u003c\/strong\u003e - suitable for tight spaces\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1660\" data-end=\"1733\"\u003e\n\u003cp data-start=\"1662\" data-end=\"1733\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1662\" data-end=\"1682\"\u003eEasy installation\u003c\/strong\u003e - snap-on transformer with mounting feet\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1740\" data-end=\"1754\"\u003e\u003cstrong data-start=\"1743\" data-end=\"1754\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\u003c\/p\u003e\u003cul data-start=\"1756\" data-end=\"1979\"\u003e\n\u003cli data-start=\"1756\" data-end=\"1789\"\u003e\n\u003cp data-start=\"1758\" data-end=\"1789\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSwitchboards in industry and households\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1790\" data-end=\"1842\"\u003e\n\u003cp data-start=\"1792\" data-end=\"1842\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement and monitoring systems for electricity\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1843\" data-end=\"1899\"\u003e\n\u003cp data-start=\"1845\" data-end=\"1899\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnection of meters, electricity meters, and circuit breakers\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1900\" data-end=\"1979\"\u003e\n\u003cp data-start=\"1902\" data-end=\"1979\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eControl of power loads and monitoring of consumption in high-current circuits\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ONKA","offers":[{"title":"Default Title","offer_id":51205667455304,"sku":"80011769","price":39.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/432f4eed3322e38a9aa3ecb198004b3b.jpg?v=1755805536","url":"https:\/\/pelek-de.com\/en\/products\/onka-stromwandler-stromwandler-1000-5a-80mm-class-0-5s-15va-80011769-tk8010005309","provider":"Deutschland Pelek","version":"1.0","type":"link"}