{"product_id":"mikroprozessor-pid-temperaturregler-fur-relaistafel-ssr-ausgang-bis-zu-1750-c","title":"Microprocessor PID temperature controller for relay panel + SSR output up to 1750 °C","description":"\u003ch1 data-start=\"117\" data-end=\"229\"\u003e\u003cstrong data-start=\"119\" data-end=\"229\"\u003e\u003cfont style=\"font-size: 18px;\"\u003ePID temperature controller - panel mounting, relay + SSR output, range -100 °C to +1750 °C (TENSE, Turkey)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003ch2 data-start=\"231\" data-end=\"252\"\u003e\u003cstrong data-start=\"234\" data-end=\"252\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp data-start=\"253\" data-end=\"477\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe professional PID temperature controller from \u003cstrong data-start=\"304\" data-end=\"313\"\u003eTENSE\u003c\/strong\u003e is designed for precise control and monitoring of thermal processes in heating, ventilation, and air conditioning systems as well as in industrial automation and process lines.\u003c\/font\u003e\u003c\/p\u003e\u003cp data-start=\"479\" data-end=\"664\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIn addition to the classic \u003cstrong data-start=\"503\" data-end=\"513\"\u003eON\/OFF control\u003c\/strong\u003e, it offers a \u003cstrong data-start=\"523\" data-end=\"550\"\u003efull PID control\u003c\/strong\u003e with auto-tuning, which significantly reduces temperature spikes and ensures a stable process flow.\u003c\/font\u003e\u003c\/p\u003e\u003cp data-start=\"666\" data-end=\"844\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller supports a wide range of sensors - thermocouples \u003cstrong data-start=\"722\" data-end=\"739\"\u003eJ, K, T, S, R, and\u003c\/strong\u003e resistance sensors \u003cstrong data-start=\"758\" data-end=\"767\"\u003ePt100\u003c\/strong\u003e. Thanks to the SSR output, it can also be easily connected to semiconductor relays.\u003c\/font\u003e\u003c\/p\u003e\u003ch1 data-start=\"851\" data-end=\"883\"\u003e\u003cstrong data-start=\"853\" data-end=\"883\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain functions and features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003cul data-start=\"884\" data-end=\"1633\"\u003e\n\u003cli data-start=\"884\" data-end=\"951\"\u003e\n\u003cp data-start=\"886\" data-end=\"951\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"886\" data-end=\"902\"\u003ePID control\u003c\/strong\u003e (selectable modes: \u003cstrong data-start=\"922\" data-end=\"948\"\u003eP, PI, PD, PID, ON\/OFF\u003c\/strong\u003e)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"952\" data-end=\"1053\"\u003e\n\u003cp data-start=\"954\" data-end=\"1053\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"954\" data-end=\"994\"\u003ePID autotuning\u003c\/strong\u003e - minimizes overshoot and efficiently optimizes the process\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1054\" data-end=\"1134\"\u003e\n\u003cp data-start=\"1056\" data-end=\"1134\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1056\" data-end=\"1078\"\u003eAnti-windup function\u003c\/strong\u003e - suppresses error accumulation under extreme conditions\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1135\" data-end=\"1192\"\u003e\n\u003cp data-start=\"1137\" data-end=\"1192\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1137\" data-end=\"1154\"\u003eON\/OFF control\u003c\/strong\u003e - simple on\/off mode\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1193\" data-end=\"1235\"\u003e\n\u003cp data-start=\"1195\" data-end=\"1235\"\u003e\u003cstrong data-start=\"1195\" data-end=\"1233\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePower-on delay in cooling operation\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1236\" data-end=\"1299\"\u003e\n\u003cp data-start=\"1238\" data-end=\"1299\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1238\" data-end=\"1254\"\u003eEEPROM memory\u003c\/strong\u003e - saves settings even during power failure\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1300\" data-end=\"1333\"\u003e\n\u003cp data-start=\"1302\" data-end=\"1333\"\u003e\u003cstrong data-start=\"1302\" data-end=\"1331\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHessle setting protection\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1334\" data-end=\"1407\"\u003e\n\u003cp data-start=\"1336\" data-end=\"1407\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1336\" data-end=\"1364\"\u003eHigh-contrast display\u003c\/strong\u003e - clear reading even under poor conditions\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1408\" data-end=\"1452\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1452\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1410\" data-end=\"1429\"\u003eRelay outputs\u003c\/strong\u003e NO+NC (250 VAC, 2 A)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1453\" data-end=\"1531\"\u003e\n\u003cp data-start=\"1455\" data-end=\"1531\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1455\" data-end=\"1470\"\u003eSSR output:\u003c\/strong\u003e max. 12 V DC, 20 mA - suitable for external semiconductor relays\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1532\" data-end=\"1595\"\u003e\n\u003cp data-start=\"1534\" data-end=\"1595\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1534\" data-end=\"1571\"\u003eMeasuring range -100 °C to +1750 °C\u003c\/strong\u003e (depending on the sensor used)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1596\" data-end=\"1633\"\u003e\n\u003cp data-start=\"1598\" data-end=\"1633\"\u003e\u003cstrong data-start=\"1598\" data-end=\"1633\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eResolution \/ measurement step: 0.1 °C\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch1 data-start=\"1640\" data-end=\"1666\"\u003e\u003cstrong data-start=\"1642\" data-end=\"1666\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCompatible sensors\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003cp data-start=\"1667\" data-end=\"1729\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller is compatible with all common industrial sensors:\u003c\/font\u003e\u003c\/p\u003e\u003ch3 data-start=\"1731\" data-end=\"1756\"\u003e\u003cstrong data-start=\"1735\" data-end=\"1756\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThermocouples (T\/C)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"1757\" data-end=\"1828\"\u003e\n\u003cli data-start=\"1757\" data-end=\"1798\"\u003e\n\u003cp data-start=\"1759\" data-end=\"1798\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eType \u003cstrong data-start=\"1763\" data-end=\"1768\"\u003eJ\u003c\/strong\u003e, \u003cstrong data-start=\"1770\" data-end=\"1775\"\u003eK\u003c\/strong\u003e, \u003cstrong data-start=\"1777\" data-end=\"1782\"\u003eT\u003c\/strong\u003e, \u003cstrong data-start=\"1784\" data-end=\"1789\"\u003eS\u003c\/strong\u003e, \u003cstrong data-start=\"1791\" data-end=\"1796\"\u003eR\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1799\" data-end=\"1828\"\u003e\n\u003cp data-start=\"1801\" data-end=\"1828\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasuring range depending on thermocouple type\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1830\" data-end=\"1853\"\u003e\u003cstrong data-start=\"1834\" data-end=\"1853\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eResistance sensors\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"1854\" data-end=\"1865\"\u003e\n\u003cli data-start=\"1854\" data-end=\"1865\"\u003e\n\u003cp data-start=\"1856\" data-end=\"1865\"\u003e\u003cstrong data-start=\"1856\" data-end=\"1865\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePt100\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch1 data-start=\"1872\" data-end=\"1902\"\u003e\u003cstrong data-start=\"1874\" data-end=\"1902\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRecommended accessories\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003cp data-start=\"1903\" data-end=\"2064\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFor the controller, we recommend ordering thermocouples type \u003cstrong data-start=\"1955\" data-end=\"1969\"\u003eJ Fe-Const\u003c\/strong\u003e, metric 6\/8 mm, with a temperature range of \u003cstrong data-start=\"2016\" data-end=\"2038\"\u003e-100 °C to +600 °C\u003c\/strong\u003e.\u003cbr data-start=\"2039\" data-end=\"2042\"\u003eAvailable cable lengths:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"2065\" data-end=\"2124\"\u003e\n\u003cli data-start=\"2065\" data-end=\"2072\"\u003e\n\u003cp data-start=\"2067\" data-end=\"2072\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e1 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2073\" data-end=\"2082\"\u003e\n\u003cp data-start=\"2075\" data-end=\"2082\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e1,5 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2083\" data-end=\"2090\"\u003e\n\u003cp data-start=\"2085\" data-end=\"2090\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e2 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2091\" data-end=\"2100\"\u003e\n\u003cp data-start=\"2093\" data-end=\"2100\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e2,5 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2101\" data-end=\"2108\"\u003e\n\u003cp data-start=\"2103\" data-end=\"2108\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e3 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2109\" data-end=\"2116\"\u003e\n\u003cp data-start=\"2111\" data-end=\"2116\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e4 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2117\" data-end=\"2124\"\u003e\n\u003cp data-start=\"2119\" data-end=\"2124\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e5 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch1 data-start=\"2131\" data-end=\"2152\"\u003e\u003cstrong data-start=\"2133\" data-end=\"2152\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTypical application\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\u003c\/p\u003e\u003cul data-start=\"2153\" data-end=\"2408\"\u003e\n\u003cli data-start=\"2153\" data-end=\"2183\"\u003e\n\u003cp data-start=\"2155\" data-end=\"2183\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndustrial ovens and heating devices\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2184\" data-end=\"2214\"\u003e\n\u003cp data-start=\"2186\" data-end=\"2214\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eControl of heating elements (TEN)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2215\" data-end=\"2258\"\u003e\n\u003cp data-start=\"2217\" data-end=\"2258\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTemperature control in boilers and heat exchangers\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2259\" data-end=\"2297\"\u003e\n\u003cp data-start=\"2261\" data-end=\"2297\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAir conditioning and ventilation systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2298\" data-end=\"2331\"\u003e\n\u003cp data-start=\"2300\" data-end=\"2331\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFood processing and production lines\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2332\" data-end=\"2357\"\u003e\n\u003cp data-start=\"2334\" data-end=\"2357\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLaboratory equipment\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2358\" data-end=\"2408\"\u003e\n\u003cp data-start=\"2360\" data-end=\"2408\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDryers, incubators, heaters, and cooling systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"48 mm x 48 mm","offer_id":51205750325576,"sku":"DT-48EM","price":44.05,"currency_code":"EUR","in_stock":true},{"title":"72 mm x 72 mm","offer_id":51205750358344,"sku":"DT-72EM","price":41.3,"currency_code":"EUR","in_stock":true},{"title":"96 mm x 96 mm","offer_id":51205750423880,"sku":"DT-96EM","price":43.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/file_fdc7a46c-f0f9-4200-b99b-f78d97af256a.png?v=1755806977","url":"https:\/\/pelek-de.com\/en\/products\/mikroprozessor-pid-temperaturregler-fur-relaistafel-ssr-ausgang-bis-zu-1750-c","provider":"Deutschland Pelek","version":"1.0","type":"link"}