{"product_id":"hydrophore-sequenzrelais-mit-zeitschaltuhr","title":"Hydrophore sequence relay with timer","description":"\u003ch1 data-start=\"115\" data-end=\"174\"\u003e\u003cstrong data-start=\"117\" data-end=\"174\"\u003e\u003cfont style=\"font-size: 16px;\"\u003eSequential hydrophore relay with timer for 2 pumps\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003ch2 data-start=\"176\" data-end=\"199\"\u003e\u003cstrong data-start=\"179\" data-end=\"197\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp data-start=\"200\" data-end=\"321\"\u003eThe sequential hydrophore relay is designed for \u003cstrong data-start=\"241\" data-end=\"273\"\u003econtrolling the operation of two pumps\u003c\/strong\u003e depending on system pressure.\u003cbr data-start=\"306\" data-end=\"309\"\u003e\nIt offers:\u003c\/p\u003e\u003cul data-start=\"322\" data-end=\"532\"\u003e\n\u003cli data-start=\"322\" data-end=\"397\"\u003e\n\u003cp data-start=\"324\" data-end=\"397\"\u003eEven \u003cstrong data-start=\"335\" data-end=\"356\"\u003epump rotation\u003c\/strong\u003e to extend system lifespan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"398\" data-end=\"469\"\u003e\n\u003cp data-start=\"400\" data-end=\"469\"\u003e\u003cstrong data-start=\"400\" data-end=\"435\"\u003eSynchronized operation of pumps\u003c\/strong\u003e when multiple booster systems are required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"470\" data-end=\"532\"\u003e\n\u003cp data-start=\"472\" data-end=\"532\"\u003e\u003cstrong data-start=\"472\" data-end=\"497\"\u003eAutomatic control\u003c\/strong\u003e depending on the current system pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"539\" data-end=\"559\"\u003e\u003cstrong data-start=\"542\" data-end=\"559\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cul data-start=\"560\" data-end=\"825\"\u003e\n\u003cli data-start=\"560\" data-end=\"608\"\u003e\n\u003cp data-start=\"562\" data-end=\"608\"\u003eControl of two pumps in a hydrophore system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"609\" data-end=\"656\"\u003e\n\u003cp data-start=\"611\" data-end=\"656\"\u003eAlternating pump operation for even wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"657\" data-end=\"712\"\u003e\n\u003cp data-start=\"659\" data-end=\"712\"\u003eTimer to set delay between pump starts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"713\" data-end=\"769\"\u003e\n\u003cp data-start=\"715\" data-end=\"769\"\u003eOption to connect additional boosters for larger systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"770\" data-end=\"825\"\u003e\n\u003cp data-start=\"772\" data-end=\"825\"\u003eProtection of pumps against overload and overflow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"832\" data-end=\"860\"\u003e\u003cstrong data-start=\"835\" data-end=\"858\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp data-start=\"861\" data-end=\"968\"\u003e\u003cem data-start=\"861\" data-end=\"966\"\u003e(if you have exact values, we can add them, e.g., power supply, power, operating range, mounting, etc.)\u003c\/em\u003e\u003c\/p\u003e\u003cul data-start=\"970\" data-end=\"1078\"\u003e\n\u003cli data-start=\"970\" data-end=\"991\"\u003e\n\u003cp data-start=\"972\" data-end=\"991\"\u003eNumber of pumps: 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"992\" data-end=\"1026\"\u003e\n\u003cp data-start=\"994\" data-end=\"1026\"\u003eMounting type: DIN rail \/ panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1078\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1078\"\u003eFunctions: Alternation, timer, pressure control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1085\" data-end=\"1099\"\u003e\u003cstrong data-start=\"1088\" data-end=\"1099\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\u003c\/p\u003e\u003cul data-start=\"1100\" data-end=\"1286\"\u003e\n\u003cli data-start=\"1100\" data-end=\"1150\"\u003e\n\u003cp data-start=\"1102\" data-end=\"1150\"\u003eWater systems with hydrophores and pressure tanks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1151\" data-end=\"1183\"\u003e\n\u003cp data-start=\"1153\" data-end=\"1183\"\u003eDomestic and industrial applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1184\" data-end=\"1237\"\u003e\n\u003cp data-start=\"1186\" data-end=\"1237\"\u003eEnsuring consistent operation and protection of pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1238\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1286\"\u003eControl of booster systems in multi-pump setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51205767364936,"sku":"HSR-02X","price":54.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/d059fb446486058e2c0ef96b20274041.png?v=1755807227","url":"https:\/\/pelek-de.com\/en\/products\/hydrophore-sequenzrelais-mit-zeitschaltuhr","provider":"Deutschland Pelek","version":"1.0","type":"link"}