{"product_id":"flussigkeitsstandrelais-fur-dampfkessel","title":"Liquid level relay for steam boilers","description":"\u003ch1 data-start=\"172\" data-end=\"268\"\u003e\u003cstrong data-start=\"174\" data-end=\"268\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eWater level relay for a tank with heating protection - Tense SSR-09\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"270\" data-end=\"291\"\u003e\u003cstrong data-start=\"273\" data-end=\"291\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"292\" data-end=\"593\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe SSR-09 relay from \u003cstrong data-start=\"319\" data-end=\"328\"\u003eTense\u003c\/strong\u003e is a modern device for \u003cstrong data-start=\"360\" data-end=\"398\"\u003eautomatic water level control\u003c\/strong\u003e in boilers, storage tanks, and water heaters.\u003cbr data-start=\"440\" data-end=\"443\"\u003eIt ensures a \u003cstrong data-start=\"453\" data-end=\"483\"\u003ereliable water supply\u003c\/strong\u003e, \u003cstrong data-start=\"485\" data-end=\"512\"\u003etimely pump shutdown\u003c\/strong\u003e, and above all an effective \u003cstrong data-start=\"533\" data-end=\"592\"\u003edry run protection of the electric heating element\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"595\" data-end=\"730\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe device monitors the water level with capacitive electrodes and automatically controls the pump and heating according to the current situation in the tank.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"737\" data-end=\"758\"\u003e\u003cstrong data-start=\"740\" data-end=\"758\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe main advantages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"759\" data-end=\"1363\"\u003e\n\u003cli data-start=\"759\" data-end=\"852\"\u003e\n\u003cp data-start=\"761\" data-end=\"852\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"761\" data-end=\"792\"\u003eDry run protection\u003c\/strong\u003e for both the boiler and the heater - extends the lifespan of the devices.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"966\"\u003e\n\u003cp data-start=\"855\" data-end=\"966\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"855\" data-end=\"892\"\u003eAutomatic water level control\u003c\/strong\u003e: The pump switches on when the water level is low and switches off when it reaches the upper limit.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"967\" data-end=\"1077\"\u003e\n\u003cp data-start=\"969\" data-end=\"1077\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"969\" data-end=\"989\"\u003eHeating protection\u003c\/strong\u003e - if no water is present in the heating system, the device immediately cuts off the power supply.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1078\" data-end=\"1152\"\u003e\n\u003cp data-start=\"1080\" data-end=\"1152\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1080\" data-end=\"1104\"\u003eLED display of\u003c\/strong\u003e pump and \u003cstrong data-start=\"1080\" data-end=\"1104\"\u003eheating operation\u003c\/strong\u003e for easy status monitoring.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1153\" data-end=\"1231\"\u003e\n\u003cp data-start=\"1155\" data-end=\"1231\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1155\" data-end=\"1179\"\u003eEasy Installation\u003c\/strong\u003e - Mounting on DIN rail, clear screw terminals.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1232\" data-end=\"1274\"\u003e\n\u003cp data-start=\"1234\" data-end=\"1274\"\u003e\u003cstrong data-start=\"1234\" data-end=\"1272\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCompact dimensions, low power consumption.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1275\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1277\" data-end=\"1363\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1322\"\u003eWide operating voltage range of 170-260 VAC\u003c\/strong\u003e - stable operation even with voltage fluctuations.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1370\" data-end=\"1393\"\u003e\u003cstrong data-start=\"1373\" data-end=\"1393\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating principle\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1394\" data-end=\"1450\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe SSR-09 operates with two electrodes located in the tank:\u003c\/font\u003e\u003c\/p\u003e\n\u003col data-start=\"1452\" data-end=\"1837\"\u003e\n\u003cli data-start=\"1452\" data-end=\"1589\"\u003e\n\u003cp data-start=\"1455\" data-end=\"1491\"\u003e\u003cstrong data-start=\"1455\" data-end=\"1489\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLower electrode (min. fill level)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1495\" data-end=\"1589\"\u003e\n\u003cli data-start=\"1495\" data-end=\"1589\"\u003e\n\u003cp data-start=\"1497\" data-end=\"1589\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the water level falls below this electrode, the relay activates the pump and starts pumping water.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1591\" data-end=\"1694\"\u003e\n\u003cp data-start=\"1594\" data-end=\"1630\"\u003e\u003cstrong data-start=\"1594\" data-end=\"1628\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe upper electrode (max. fill level)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1634\" data-end=\"1694\"\u003e\n\u003cli data-start=\"1634\" data-end=\"1694\"\u003e\n\u003cp data-start=\"1636\" data-end=\"1694\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen the upper level is reached, the relay automatically switches off the pump.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1696\" data-end=\"1837\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1740\"\u003e\u003cstrong data-start=\"1699\" data-end=\"1738\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtective electrode on the heating element\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1744\" data-end=\"1837\"\u003e\n\u003cli data-start=\"1744\" data-end=\"1837\"\u003e\n\u003cp data-start=\"1746\" data-end=\"1837\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf there is no water in the heating element, the relay interrupts the power supply to the heating element and prevents overheating.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"1839\" data-end=\"1915\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThis intelligent logic ensures safe and economical operation of the entire system.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"1922\" data-end=\"1936\"\u003e\u003cstrong data-start=\"1925\" data-end=\"1936\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUse of\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1937\" data-end=\"2133\"\u003e\n\u003cli data-start=\"1937\" data-end=\"1985\"\u003e\n\u003cp data-start=\"1939\" data-end=\"1985\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eElectric boilers and water heaters\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1986\" data-end=\"2023\"\u003e\n\u003cp data-start=\"1988\" data-end=\"2023\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHeating systems with buffer tanks\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2024\" data-end=\"2062\"\u003e\n\u003cp data-start=\"2026\" data-end=\"2062\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWater storage for households and industry\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2063\" data-end=\"2092\"\u003e\n\u003cp data-start=\"2065\" data-end=\"2092\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWaterworks and pumping systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2093\" data-end=\"2133\"\u003e\n\u003cp data-start=\"2095\" data-end=\"2133\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDrinking and utility water storage tanks\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2140\" data-end=\"2168\"\u003e\u003cstrong data-start=\"2143\" data-end=\"2168\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eInstallation and connection\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2169\" data-end=\"2404\"\u003e\n\u003cli data-start=\"2169\" data-end=\"2220\"\u003e\n\u003cp data-start=\"2171\" data-end=\"2220\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMounting on \u003cstrong data-start=\"2192\" data-end=\"2205\"\u003estandard DIN rail\u003c\/strong\u003e in the control cabinet.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2221\" data-end=\"2264\"\u003e\n\u003cp data-start=\"2223\" data-end=\"2264\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnection via \u003cstrong data-start=\"2240\" data-end=\"2261\"\u003escrew terminals\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2265\" data-end=\"2331\"\u003e\n\u003cp data-start=\"2267\" data-end=\"2331\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe electrodes must be installed in the tanks at the required heights.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2332\" data-end=\"2404\"\u003e\n\u003cp data-start=\"2334\" data-end=\"2404\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFor stable operation, the manufacturer recommends using conductors \u003cstrong data-start=\"2387\" data-end=\"2403\"\u003ewith at least 2.5 mm²\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2406\" data-end=\"2499\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2406\" data-end=\"2419\" style=\"\"\u003eNote:\u003c\/strong\u003e The electrodes (level probes) are not included in the delivery and must be ordered separately.\u003c\/font\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51205744951624,"sku":"SSR-09","price":15.52,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/331942fa669f949c300016097ee9dafe.png?v=1755806867","url":"https:\/\/pelek-de.com\/en\/products\/flussigkeitsstandrelais-fur-dampfkessel","provider":"Deutschland Pelek","version":"1.0","type":"link"}