{"product_id":"flussigkeitsstandrelais-fur-dampfkessel-brunnen-oder-tank","title":"Liquid level relay for steam boilers (well or tank)","description":"\u003ch1 data-start=\"123\" data-end=\"184\"\u003e\u003cstrong data-start=\"125\" data-end=\"184\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eRelay for water level control in boilers and steam generators\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"186\" data-end=\"207\"\u003e\u003cstrong data-start=\"189\" data-end=\"207\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"208\" data-end=\"485\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe water level relay is intended for use in \u003cstrong data-start=\"263\" data-end=\"316\"\u003eheating boilers, steam generators, and water heating systems\u003c\/strong\u003e, where it ensures automatic shutdown of the electric heating system if there is insufficient water in the tank.\u003cbr data-start=\"401\" data-end=\"404\"\u003eIt prevents the heater from running \"dry,\" thus protecting the system and extending its lifespan.\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"487\" data-end=\"600\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe device operates with two independent power systems - \u003cstrong data-start=\"547\" data-end=\"570\"\u003eTANK (well\/tank)\u003c\/strong\u003e and \u003cstrong data-start=\"573\" data-end=\"599\"\u003eBOILER (boiler\/heating)\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"607\" data-end=\"628\"\u003e\u003cstrong data-start=\"609\" data-end=\"628\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEquipment functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch3 data-start=\"629\" data-end=\"667\"\u003e\u003cstrong data-start=\"633\" data-end=\"667\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTank level control (TANK)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"668\" data-end=\"833\"\u003e\n\u003cli data-start=\"668\" data-end=\"767\"\u003e\n\u003cp data-start=\"670\" data-end=\"767\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAs long as the water level is \u003cstrong data-start=\"692\" data-end=\"715\"\u003eabove the TANK electrode\u003c\/strong\u003e, the pump runs (the \"Motor running\" indicator lights up).\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"768\" data-end=\"833\"\u003e\n\u003cp data-start=\"770\" data-end=\"833\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the water level falls \u003cstrong data-start=\"791\" data-end=\"813\"\u003ebelow the TANK electrode\u003c\/strong\u003e, the pump switches off.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"835\" data-end=\"883\"\u003e\u003cstrong data-start=\"839\" data-end=\"883\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLevel control boiler\/heating (BOILER)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"884\" data-end=\"1106\"\u003e\n\u003cli data-start=\"884\" data-end=\"962\"\u003e\n\u003cp data-start=\"886\" data-end=\"962\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen the \u003cstrong data-start=\"915\" data-end=\"925\"\u003eBOILER level\u003c\/strong\u003e is reached, the pump switches off - the tank is full.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"963\" data-end=\"1106\"\u003e\n\u003cp data-start=\"965\" data-end=\"1106\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the level in the boiler falls \u003cstrong data-start=\"994\" data-end=\"1018\"\u003ebelow the BOILER electrode\u003c\/strong\u003e, a 10-second delay is triggered, after which the pump automatically switches on and refills the water.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1108\" data-end=\"1159\"\u003e\u003cstrong data-start=\"1112\" data-end=\"1159\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eElectric control of hot water preparation (RES Elect)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1160\" data-end=\"1343\"\u003e\n\u003cli data-start=\"1160\" data-end=\"1249\"\u003e\n\u003cp data-start=\"1162\" data-end=\"1249\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen the water level in the boiler reaches the \u003cstrong data-start=\"1196\" data-end=\"1209\"\u003eRES Elect value\u003c\/strong\u003e, the heater switches on (control light off).\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1250\" data-end=\"1343\"\u003e\n\u003cp data-start=\"1252\" data-end=\"1343\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the level falls below the \u003cstrong data-start=\"1287\" data-end=\"1300\"\u003eRES\u003c\/strong\u003e Elect, the heater switches off and the control light turns on.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1345\" data-end=\"1420\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThis function protects the heater from overheating or damage when the tank is empty.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"1427\" data-end=\"1451\"\u003e\u003cstrong data-start=\"1429\" data-end=\"1451\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWiring (overview)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul data-start=\"1452\" data-end=\"1858\"\u003e\n\u003cli data-start=\"1452\" data-end=\"1588\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1588\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1454\" data-end=\"1467\"\u003eCom Elect\u003c\/strong\u003e - common electrode (must be connected to the metal body of the tank\/boiler; if not conductive, use a separate electrode)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1589\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1591\" data-end=\"1644\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1591\" data-end=\"1605\"\u003eTank Elect\u003c\/strong\u003e - fill level electrode for well\/tank\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1693\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1693\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1663\"\u003eBoiler Elect\u003c\/strong\u003e - electrode for boiler fill level\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1694\" data-end=\"1743\"\u003e\n\u003cp data-start=\"1696\" data-end=\"1743\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1696\" data-end=\"1709\"\u003eRes Elect\u003c\/strong\u003e - electrode for heating control\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1744\" data-end=\"1791\"\u003e\n\u003cp data-start=\"1746\" data-end=\"1791\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1746\" data-end=\"1757\"\u003eRes Out\u003c\/strong\u003e - output for heating connection\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1792\" data-end=\"1858\"\u003e\n\u003cp data-start=\"1794\" data-end=\"1858\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1794\" data-end=\"1807\"\u003eWater Not\u003c\/strong\u003e - output for signal lamp (no water)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-start=\"1865\" data-end=\"1890\"\u003e\u003cstrong data-start=\"1867\" data-end=\"1890\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eImportant note\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul data-start=\"1891\" data-end=\"2184\"\u003e\n\u003cli data-start=\"1891\" data-end=\"1962\"\u003e\n\u003cp data-start=\"1893\" data-end=\"1962\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1893\" data-end=\"1929\"\u003eThe electrodes are not included\u003c\/strong\u003e - they must be ordered separately.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1963\" data-end=\"2059\"\u003e\n\u003cp data-start=\"1965\" data-end=\"2059\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWe also recommend purchasing \u003cstrong data-start=\"1992\" data-end=\"2014\"\u003e3 pieces of 2-A circuit breakers\u003c\/strong\u003e to protect the input and output circuits.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2109\"\u003e\n\u003cp data-start=\"2062\" data-end=\"2109\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWire the relay \u003cstrong data-start=\"2075\" data-end=\"2106\"\u003eexactly according to the manufacturer's wiring diagram\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2110\" data-end=\"2184\"\u003e\n\u003cp data-start=\"2112\" data-end=\"2184\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the socket is not conductive, a special common electrode must be used.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-start=\"2191\" data-end=\"2216\"\u003e\u003cstrong data-start=\"2193\" data-end=\"2216\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul data-start=\"2217\" data-end=\"2461\"\u003e\n\u003cli data-start=\"2217\" data-end=\"2251\"\u003e\n\u003cp data-start=\"2219\" data-end=\"2251\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2219\" data-end=\"2240\"\u003eRated voltage:\u003c\/strong\u003e 220 V AC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2252\" data-end=\"2292\"\u003e\n\u003cp data-start=\"2254\" data-end=\"2292\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2254\" data-end=\"2281\"\u003eOperating voltage range:\u003c\/strong\u003e 90-110%\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2320\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2320\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2295\" data-end=\"2309\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2321\" data-end=\"2343\"\u003e\n\u003cp data-start=\"2323\" data-end=\"2343\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2323\" data-end=\"2334\"\u003ePower consumption:\u003c\/strong\u003e \u0026lt; 3 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2344\" data-end=\"2380\"\u003e\n\u003cp data-start=\"2346\" data-end=\"2380\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2346\" data-end=\"2367\"\u003eOperating temperature:\u003c\/strong\u003e -40...+50 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2381\" data-end=\"2415\"\u003e\n\u003cp data-start=\"2383\" data-end=\"2415\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2383\" data-end=\"2397\"\u003eConnection:\u003c\/strong\u003e Screw terminals\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2416\" data-end=\"2461\"\u003e\n\u003cp data-start=\"2418\" data-end=\"2461\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2418\" data-end=\"2429\"\u003eMounting:\u003c\/strong\u003e DIN rail or mounting plate\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong data-start=\"2470\" data-end=\"2486\" style=\"font-family: inherit; color: rgb(25, 32, 39); font-size: 28px;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePackage contents\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cul data-start=\"2487\" data-end=\"2593\"\u003e\n\u003cli data-start=\"2487\" data-end=\"2521\"\u003e\n\u003cp data-start=\"2489\" data-end=\"2521\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelay for water level control\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2522\" data-end=\"2593\"\u003e\n\u003cp data-start=\"2524\" data-end=\"2593\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDocumentation \/ Wiring diagram\u003cbr data-start=\"2553\" data-end=\"2556\"\u003e\u003cem data-start=\"2556\" data-end=\"2593\" style=\"\"\u003e(Electrodes not included)\u003c\/em\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51205744394568,"sku":"SSR-19","price":16.64,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/1f260439db01cbf624587c651e27f3cf.png?v=1755806855","url":"https:\/\/pelek-de.com\/en\/products\/flussigkeitsstandrelais-fur-dampfkessel-brunnen-oder-tank","provider":"Deutschland Pelek","version":"1.0","type":"link"}