{"product_id":"dta-72-digitales-temperaturstufen-steuerrelais","title":"DTA-72 Digital Temperature Level Control Relay","description":"\u003ch1 data-start=\"100\" data-end=\"177\"\u003e\u003cstrong data-start=\"102\" data-end=\"175\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eTENSE dual-band PID temperature controller with timer and heating profile\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch3 data-start=\"179\" data-end=\"192\"\u003e\u003cstrong data-start=\"183\" data-end=\"192\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDescription\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"193\" data-end=\"547\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe TENSE dual-band thermostat is a \u003cstrong data-start=\"224\" data-end=\"257\"\u003eprogrammable PID controller\u003c\/strong\u003e that automatically sets parameters for precise temperature control. It allows \u003cstrong data-start=\"333\" data-end=\"366\"\u003e12\/20 programmable steps\u003c\/strong\u003e with separate time intervals, monitors current temperature and time, and supports \u003cstrong data-start=\"455\" data-end=\"487\"\u003eboth relative and absolute alarms\u003c\/strong\u003e. The controller is suitable for panel or device installation.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"554\" data-end=\"575\"\u003e\u003cstrong data-start=\"558\" data-end=\"575\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain advantages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"576\" data-end=\"1033\"\u003e\n\u003cli data-start=\"576\" data-end=\"638\"\u003e\n\u003cp data-start=\"578\" data-end=\"638\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic PID parameter adjustment (\u003cstrong data-start=\"622\" data-end=\"635\"\u003eAuto-Tune function\u003c\/strong\u003e)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"639\" data-end=\"686\"\u003e\n\u003cp data-start=\"641\" data-end=\"686\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e20 programmable steps, up to 18 h per step\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"687\" data-end=\"748\"\u003e\n\u003cp data-start=\"689\" data-end=\"748\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of current step, temperature, time, and process status\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"749\" data-end=\"783\"\u003e\n\u003cp data-start=\"751\" data-end=\"783\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelative or absolute alarm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"784\" data-end=\"838\"\u003e\n\u003cp data-start=\"786\" data-end=\"838\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEEPROM memory stores parameters during power failure\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"839\" data-end=\"866\"\u003e\n\u003cp data-start=\"841\" data-end=\"866\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eParameter protection by code\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"867\" data-end=\"926\"\u003e\n\u003cp data-start=\"869\" data-end=\"926\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOptional sensor type: thermocouple (J, K, S) or Pt100\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"927\" data-end=\"981\"\u003e\n\u003cp data-start=\"929\" data-end=\"981\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cstrong data-start=\"936\" data-end=\"951\"\u003eAnti-windup function\u003c\/strong\u003e to prevent error accumulation\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"982\" data-end=\"1033\"\u003e\n\u003cp data-start=\"984\" data-end=\"1033\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOption to connect a \u003cstrong data-start=\"1002\" data-end=\"1031\"\u003esemiconductor relay (SSR)\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1040\" data-end=\"1069\"\u003e\u003cstrong data-start=\"1044\" data-end=\"1069\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1070\" data-end=\"1084\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1070\" data-end=\"1081\"\u003eDisplay\u003c\/strong\u003e:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1085\" data-end=\"1194\"\u003e\n\u003cli data-start=\"1085\" data-end=\"1146\"\u003e\n\u003cp data-start=\"1087\" data-end=\"1146\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e4-digit seven-segment display for the current temperature (PV)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1147\" data-end=\"1194\"\u003e\n\u003cp data-start=\"1149\" data-end=\"1194\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e4-digit display for the set temperature (SV)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1196\" data-end=\"1224\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1196\" data-end=\"1221\"\u003eTemperature measurement range\u003c\/strong\u003e:\u003c\/font\u003e\u003c\/p\u003e\u003cp data-start=\"1196\" data-end=\"1224\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003c\/font\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor type\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e-100 ... +600 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e-100 ... +1300 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003e0 ... +1750 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePt100\u003c\/td\u003e\n\u003ctd\u003e-100 ... +600 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cbr\u003e\u003cul data-start=\"1370\" data-end=\"1457\"\u003e\n\u003cli data-start=\"1391\" data-end=\"1427\"\u003e\n\u003cp data-start=\"1393\" data-end=\"1427\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement accuracy: ±0.3% of scale\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1428\" data-end=\"1457\"\u003e\n\u003cp data-start=\"1430\" data-end=\"1457\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTimer accuracy: ±1.5%\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1459\" data-end=\"1509\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1459\" data-end=\"1471\"\u003eControl\u003c\/strong\u003e: ON-OFF, P, PI, PD, PID (optional)\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"1511\" data-end=\"1525\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1511\" data-end=\"1522\"\u003eOutputs\u003c\/strong\u003e:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1526\" data-end=\"1649\"\u003e\n\u003cli data-start=\"1526\" data-end=\"1598\"\u003e\n\u003cp data-start=\"1528\" data-end=\"1598\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1528\" data-end=\"1551\"\u003eHeating output (HEAT)\u003c\/strong\u003e: NO + NC relay, 250 VAC, 2 A (optional SSR)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1599\" data-end=\"1649\"\u003e\n\u003cp data-start=\"1601\" data-end=\"1649\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1601\" data-end=\"1618\"\u003eAlarm\u003c\/strong\u003e: NO + NC relay, 250 V AC, 2 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1651\" data-end=\"1671\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1651\" data-end=\"1668\"\u003ePID parameters\u003c\/strong\u003e:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1672\" data-end=\"1932\"\u003e\n\u003cli data-start=\"1672\" data-end=\"1706\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1706\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProportional band: 1-130 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1707\" data-end=\"1749\"\u003e\n\u003cp data-start=\"1709\" data-end=\"1749\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIntegration time: 0-30 min (0 = off)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1750\" data-end=\"1795\"\u003e\n\u003cp data-start=\"1752\" data-end=\"1795\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDifferentiation time: 0-10 min (0 = off)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1796\" data-end=\"1826\"\u003e\n\u003cp data-start=\"1798\" data-end=\"1826\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eControl period: 4-200 s\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1827\" data-end=\"1853\"\u003e\n\u003cp data-start=\"1829\" data-end=\"1853\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDeviation: -100 ... +100 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1854\" data-end=\"1893\"\u003e\n\u003cp data-start=\"1856\" data-end=\"1893\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCold junction compensation: 0-50 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1894\" data-end=\"1932\"\u003e\n\u003cp data-start=\"1896\" data-end=\"1932\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLead compensation (Pt100): up to 10 Ω\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1934\" data-end=\"2030\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1934\" data-end=\"1946\"\u003ePower supply\u003c\/strong\u003e: 100-240 V AC (50-60 Hz) or optional 24 V AC\/DC\u003cbr data-start=\"1997\" data-end=\"2000\"\u003e\u003cstrong data-start=\"2000\" data-end=\"2020\"\u003ePower consumption\u003c\/strong\u003e: \u0026lt; 8 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"2032\" data-end=\"2056\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2032\" data-end=\"2053\"\u003eOperating conditions\u003c\/strong\u003e:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"2057\" data-end=\"2166\"\u003e\n\u003cli data-start=\"2057\" data-end=\"2077\"\u003e\n\u003cp data-start=\"2059\" data-end=\"2077\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTemperature: 0-50 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2078\" data-end=\"2105\"\u003e\n\u003cp data-start=\"2080\" data-end=\"2105\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eStorage: -10 ... 60 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2106\" data-end=\"2136\"\u003e\n\u003cp data-start=\"2108\" data-end=\"2136\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHumidity: up to 80% at 30 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2137\" data-end=\"2166\"\u003e\n\u003cp data-start=\"2139\" data-end=\"2166\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAltitude: \u0026lt; 2000 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2168\" data-end=\"2199\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2168\" data-end=\"2196\"\u003eCertification and safety\u003c\/strong\u003e:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"2200\" data-end=\"2343\"\u003e\n\u003cli data-start=\"2200\" data-end=\"2235\"\u003e\n\u003cp data-start=\"2202\" data-end=\"2235\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEMC: EN 61000-6-1, EN 61000-6-3\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2236\" data-end=\"2296\"\u003e\n\u003cp data-start=\"2238\" data-end=\"2296\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSafety: EN 61010-1, Category I, Pollution degree 1\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2297\" data-end=\"2320\"\u003e\n\u003cp data-start=\"2299\" data-end=\"2320\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtection class: IP20\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2321\" data-end=\"2343\"\u003e\n\u003cp data-start=\"2323\" data-end=\"2343\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWeight: \u0026lt; 0.5 kg\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2350\" data-end=\"2370\"\u003e\u003cstrong data-start=\"2354\" data-end=\"2370\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdditional advantages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2371\" data-end=\"2583\"\u003e\n\u003cli data-start=\"2371\" data-end=\"2430\"\u003e\n\u003cp data-start=\"2373\" data-end=\"2430\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePID mode keeps the temperature as close as possible to the setpoint\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2431\" data-end=\"2515\"\u003e\n\u003cp data-start=\"2433\" data-end=\"2515\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSimultaneous display of current temperature, setpoint, control step, and time\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2516\" data-end=\"2583\"\u003e\n\u003cp data-start=\"2518\" data-end=\"2583\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConvenient operation with the buttons \u003cstrong data-start=\"2551\" data-end=\"2581\"\u003eSTART \/ STOP \/ PAUSE \/ SET\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51205767889224,"sku":"DTA-72","price":96.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/ee29e299f1c4fa71eacee7f1b5e2b9b4.png?v=1755807237","url":"https:\/\/pelek-de.com\/en\/products\/dta-72-digitales-temperaturstufen-steuerrelais","provider":"Deutschland Pelek","version":"1.0","type":"link"}