{"product_id":"dreiphasiges-uberwachungsrelais-mit-ptc-steuerung-phasenauslosung-asymmetrie-sequenz","title":"Three-phase monitoring relay with PTC control phase trip\/asymmetry\/sequence","description":"\u003ch2 data-start=\"152\" data-end=\"258\"\u003e\u003cstrong data-start=\"155\" data-end=\"258\"\u003eThree-phase phase-cut relay with trip protection and winding temperature monitoring, TENSE - FKV-14P\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"260\" data-end=\"282\"\u003e\u003cstrong data-start=\"264\" data-end=\"282\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"283\" data-end=\"632\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe three-phase phase protection relay FKV-14P is designed to protect three-phase electric motors and devices against critical faults in the power supply network. It provides comprehensive control of phase presence, phase failure, phase jamming, asymmetry (fixed 40%), phase shift, and excessive motor winding temperature. It is equipped with a neutral conductor and intended for DIN rail mounting.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"634\" data-end=\"655\"\u003e\u003cstrong data-start=\"638\" data-end=\"655\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"656\" data-end=\"998\"\u003e\n\u003cli data-start=\"656\" data-end=\"695\"\u003e\n\u003cp data-start=\"658\" data-end=\"695\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eChecks the presence of all three phases\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"696\" data-end=\"726\"\u003e\n\u003cp data-start=\"698\" data-end=\"726\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePhase failure protection\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"727\" data-end=\"764\"\u003e\n\u003cp data-start=\"729\" data-end=\"764\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDetection of phase jamming (kinking)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"765\" data-end=\"805\"\u003e\n\u003cp data-start=\"767\" data-end=\"805\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eControl of fixed voltage asymmetry 40%\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"806\" data-end=\"847\"\u003e\n\u003cp data-start=\"808\" data-end=\"847\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtection against incorrect phase sequence\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"848\" data-end=\"882\"\u003e\n\u003cp data-start=\"850\" data-end=\"882\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMotor winding temperature control\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"883\" data-end=\"922\"\u003e\n\u003cp data-start=\"885\" data-end=\"922\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOptical status indicator (LED OUT)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"923\" data-end=\"998\"\u003e\n\u003cp data-start=\"925\" data-end=\"998\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic restoration of operation when parameters return to the permissible range\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1000\" data-end=\"1024\"\u003e\u003cstrong data-start=\"1004\" data-end=\"1024\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating principle\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1025\" data-end=\"1646\"\u003e\n\u003cli data-start=\"1025\" data-end=\"1218\"\u003e\n\u003cp data-start=\"1027\" data-end=\"1218\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1027\" data-end=\"1047\"\u003eNormal operation:\u003c\/strong\u003e When all three mains voltages are present, the phase sequence is correct, and the winding temperature does not exceed the limits, the relay switches on (contacts 15-18 are closed) and the LED OUT lights up.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1219\" data-end=\"1370\"\u003e\n\u003cp data-start=\"1221\" data-end=\"1370\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1221\" data-end=\"1253\"\u003eVoltage error or asymmetry:\u003c\/strong\u003e If the voltage of any phase deviates by more than 40%, contacts 15-18 open and contacts 15-16 close; the LED OUT is off.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1371\" data-end=\"1450\"\u003e\n\u003cp data-start=\"1373\" data-end=\"1450\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1373\" data-end=\"1394\"\u003ePhase sequence error:\u003c\/strong\u003e The relay responds by opening the contacts and turning off the OUT LED.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1451\" data-end=\"1550\"\u003e\n\u003cp data-start=\"1453\" data-end=\"1550\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1453\" data-end=\"1483\"\u003eExceeding winding temperature:\u003c\/strong\u003e The relay switches off the output until the temperature returns within permissible limits.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1551\" data-end=\"1646\"\u003e\n\u003cp data-start=\"1553\" data-end=\"1646\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1553\" data-end=\"1574\"\u003eRestore operation:\u003c\/strong\u003e The relay automatically returns to operating status after parameters normalize.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1648\" data-end=\"1677\"\u003e\u003cstrong data-start=\"1652\" data-end=\"1677\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1678\" data-end=\"1982\"\u003e\n\u003cli data-start=\"1678\" data-end=\"1724\"\u003e\n\u003cp data-start=\"1680\" data-end=\"1724\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1680\" data-end=\"1697\"\u003eDevice type:\u003c\/strong\u003e Phase monitoring relay\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1725\" data-end=\"1750\"\u003e\n\u003cp data-start=\"1727\" data-end=\"1750\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1727\" data-end=\"1742\"\u003eNumber of phases:\u003c\/strong\u003e 3 + N\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1751\" data-end=\"1782\"\u003e\n\u003cp data-start=\"1753\" data-end=\"1782\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1753\" data-end=\"1767\"\u003eAsymmetry:\u003c\/strong\u003e 40% (fixed)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1783\" data-end=\"1819\"\u003e\n\u003cp data-start=\"1785\" data-end=\"1819\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1785\" data-end=\"1813\"\u003eWinding temperature protection:\u003c\/strong\u003e Yes\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1820\" data-end=\"1899\"\u003e\n\u003cp data-start=\"1822\" data-end=\"1899\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1822\" data-end=\"1844\"\u003eOutput contacts:\u003c\/strong\u003e 15-18 (closed during operation), 15-16 (closed during fault)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1900\" data-end=\"1925\"\u003e\n\u003cp data-start=\"1902\" data-end=\"1925\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1902\" data-end=\"1915\"\u003eDisplay:\u003c\/strong\u003e LED OUT\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1926\" data-end=\"1951\"\u003e\n\u003cp data-start=\"1928\" data-end=\"1951\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1928\" data-end=\"1939\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1952\" data-end=\"1982\"\u003e\n\u003cp data-start=\"1954\" data-end=\"1982\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1954\" data-end=\"1966\"\u003eManufacturer:\u003c\/strong\u003e TENSE (Turkey)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1984\" data-end=\"1998\"\u003e\u003cstrong data-start=\"1988\" data-end=\"1998\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdvantages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1999\" data-end=\"2236\"\u003e\n\u003cli data-start=\"1999\" data-end=\"2046\"\u003e\n\u003cp data-start=\"2001\" data-end=\"2046\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eComprehensive motor and wiring protection\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2047\" data-end=\"2092\"\u003e\n\u003cp data-start=\"2049\" data-end=\"2092\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eStable operation through fixed 40% asymmetry\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2093\" data-end=\"2126\"\u003e\n\u003cp data-start=\"2095\" data-end=\"2126\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEasy mounting on DIN rail\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2127\" data-end=\"2175\"\u003e\n\u003cp data-start=\"2129\" data-end=\"2175\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic function recovery without operator intervention\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2176\" data-end=\"2236\"\u003e\n\u003cp data-start=\"2178\" data-end=\"2236\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eReliable protection under harsh industrial conditions\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2238\" data-end=\"2261\"\u003e\u003cstrong data-start=\"2242\" data-end=\"2261\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTypical applications\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2262\" data-end=\"2415\"\u003e\n\u003cli data-start=\"2262\" data-end=\"2289\"\u003e\n\u003cp data-start=\"2264\" data-end=\"2289\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThree-phase electric motors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2290\" data-end=\"2323\"\u003e\n\u003cp data-start=\"2292\" data-end=\"2323\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndustrial pump systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2324\" data-end=\"2338\"\u003e\n\u003cp data-start=\"2326\" data-end=\"2338\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCompressors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2339\" data-end=\"2354\"\u003e\n\u003cp data-start=\"2341\" data-end=\"2354\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFans\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2355\" data-end=\"2415\"\u003e\n\u003cp data-start=\"2357\" data-end=\"2415\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMachines sensitive to phase sequence and voltage quality\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204693950792,"sku":"FKV-14P","price":23.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/b3b826fcf16fcc33ebd4f28e4b5e2edf.png?v=1755799903","url":"https:\/\/pelek-de.com\/en\/products\/dreiphasiges-uberwachungsrelais-mit-ptc-steuerung-phasenauslosung-asymmetrie-sequenz","provider":"Deutschland Pelek","version":"1.0","type":"link"}