{"product_id":"dreiphasiges-uberwachungs-schutzrelais-fur-uberspannung-unterspannung-folge-fehlersteuerung-2","title":"Three-phase monitoring\/protection relay for overvoltage, undervoltage, sequence\/fault control","description":"\u003ch1 data-start=\"184\" data-end=\"249\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"186\" data-end=\"247\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eThree-phase voltage monitoring relay - GKM-02\/02F (TENSE)\u003c\/font\u003e\u003c\/span\u003e\u003c\/h1\u003e\u003cp data-start=\"250\" data-end=\"351\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"250\" data-end=\"351\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOver-\/undervoltage monitoring - phase sequence - neutral point control - 5A output - 140-300 VAC\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp data-start=\"353\" data-end=\"709\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe three-phase monitoring relay\u003cb\u003e GKM-02\/02F\u003c\/b\u003e from \u003cspan data-start=\"404\" data-end=\"413\" style=\"font-weight: 600;\"\u003eTENSE\u003c\/span\u003e is used to protect three-phase consumers from dangerous deviations in the power supply network. The device monitors undervoltage, overvoltage, phase failure, incorrect phase sequence, and neutral conductor loss.\u003cbr data-start=\"616\" data-end=\"619\"\u003eWhen a fault is detected, the relay immediately switches off the output contact, thus protecting the connected devices.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"716\" data-end=\"741\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"719\" data-end=\"741\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey features\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cul data-start=\"743\" data-end=\"1789\"\u003e\n\u003cli data-start=\"743\" data-end=\"876\"\u003e\u003cp data-start=\"745\" data-end=\"876\"\u003e\u003cspan data-start=\"745\" data-end=\"772\" style=\"font-weight: 600;\"\u003eOvervoltage monitoring (HV):\u003c\/span\u003e\u003cbr data-start=\"772\" data-end=\"775\"\u003e- Responds to exceeding the set level in any phase\u003cbr data-start=\"835\" data-end=\"838\"\u003e- Adjustment range: \u003cspan data-start=\"860\" data-end=\"876\" style=\"font-weight: 600;\"\u003e230-300 VAC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"878\" data-end=\"997\"\u003e\u003cp data-start=\"880\" data-end=\"997\"\u003e\u003cspan data-start=\"880\" data-end=\"907\" style=\"font-weight: 600;\"\u003eUndervoltage monitoring (LV):\u003c\/span\u003e\u003cbr data-start=\"907\" data-end=\"910\"\u003e- Responds to voltage drop in any phase\u003cbr data-start=\"956\" data-end=\"959\"\u003e- Adjustment range: \u003cspan data-start=\"981\" data-end=\"997\" style=\"font-weight: 600;\"\u003e140-210 V AC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1106\"\u003e\u003cp data-start=\"1001\" data-end=\"1106\"\u003e\u003cspan data-start=\"1001\" data-end=\"1035\" style=\"font-weight: 600;\"\u003eAdjustable response time (DT):\u003c\/span\u003e\u003cbr data-start=\"1035\" data-end=\"1038\"\u003e- Delay of response to a fault condition\u003cbr data-start=\"1075\" data-end=\"1078\"\u003e- Adjustment range: \u003cspan data-start=\"1090\" data-end=\"1106\" style=\"font-weight: 600;\"\u003e0.1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1108\" data-end=\"1228\"\u003e\u003cp data-start=\"1110\" data-end=\"1228\"\u003e\u003cspan data-start=\"1110\" data-end=\"1152\" style=\"font-weight: 600;\"\u003eAutomatic reset - return time (RT):\u003c\/span\u003e\u003cbr data-start=\"1152\" data-end=\"1155\"\u003e- Power-on delay after voltage normalization\u003cbr data-start=\"1197\" data-end=\"1200\"\u003e- Range: \u003cspan data-start=\"1212\" data-end=\"1228\" style=\"font-weight: 600;\"\u003e0.1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1355\"\u003e\u003cp data-start=\"1232\" data-end=\"1355\"\u003e\u003cspan data-start=\"1232\" data-end=\"1278\" style=\"font-weight: 600;\"\u003eMonitoring of phase sequence and phase presence\u003c\/span\u003e\u003cbr data-start=\"1278\" data-end=\"1281\"\u003e- Protection against incorrect phase sequence\u003cbr data-start=\"1328\" data-end=\"1331\"\u003e- Detection of phase failure\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1357\" data-end=\"1511\"\u003e\u003cp data-start=\"1359\" data-end=\"1511\"\u003e\u003cspan data-start=\"1359\" data-end=\"1407\" style=\"font-weight: 600;\"\u003eMonitoring the presence of the neutral conductor (N)\u003c\/span\u003e\u003cbr data-start=\"1407\" data-end=\"1410\"\u003e- Protection against loss of the neutral conductor in the network\u003cbr data-start=\"1450\" data-end=\"1453\"\u003e- Disconnection when supply voltage drops below \u003cspan data-start=\"1500\" data-end=\"1511\" style=\"font-weight: 600;\"\u003e88 V AC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1591\"\u003e\u003cp data-start=\"1515\" data-end=\"1591\"\u003e\u003cspan data-start=\"1515\" data-end=\"1532\" style=\"font-weight: 600;\"\u003eHysteresis 3%\u003c\/span\u003e\u003cbr data-start=\"1532\" data-end=\"1535\"\u003e- limits unwanted rapid switching during voltage fluctuations\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1593\" data-end=\"1660\"\u003e\u003cp data-start=\"1595\" data-end=\"1660\"\u003e\u003cspan data-start=\"1595\" data-end=\"1618\" style=\"font-weight: 600;\"\u003eOptical signaling\u003c\/span\u003e\u003cbr data-start=\"1618\" data-end=\"1621\"\u003e- LED indicators for status and error type\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1662\" data-end=\"1708\"\u003e\u003cp data-start=\"1664\" data-end=\"1708\"\u003e\u003cspan data-start=\"1664\" data-end=\"1708\" style=\"font-weight: 600;\"\u003eCompact design, DIN rail mounting\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1789\"\u003e\u003cp data-start=\"1712\" data-end=\"1789\"\u003e\u003cspan data-start=\"1712\" data-end=\"1733\" style=\"font-weight: 600;\"\u003eOutput contact:\u003c\/span\u003e\u003cbr data-start=\"1733\" data-end=\"1736\"\u003e- \u003cspan data-start=\"1740\" data-end=\"1751\" style=\"font-weight: 600;\"\u003eNO + NC\u003c\/span\u003e, potential-free contact\u003cbr data-start=\"1766\" data-end=\"1769\"\u003e- \u003cspan data-start=\"1782\" data-end=\"1789\" style=\"font-weight: 600;\"\u003e5 A\u003c\/span\u003e load\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1796\" data-end=\"1810\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1799\" data-end=\"1810\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"1812\" data-end=\"1859\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe relay is designed to protect devices such as:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1861\" data-end=\"1973\"\u003e\n\u003cli data-start=\"1861\" data-end=\"1881\"\u003e\u003cp data-start=\"1863\" data-end=\"1881\"\u003ethree-phase motors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1882\" data-end=\"1896\"\u003e\u003cp data-start=\"1884\" data-end=\"1896\"\u003ecompressors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1909\"\u003e\u003cp data-start=\"1899\" data-end=\"1909\"\u003epumps\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1935\"\u003e\u003cp data-start=\"1912\" data-end=\"1935\"\u003eair conditioning units\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1936\" data-end=\"1973\"\u003e\u003cp data-start=\"1938\" data-end=\"1973\"\u003egeneral industrial and household loads\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1975\" data-end=\"1987\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtects against:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1989\" data-end=\"2087\"\u003e\n\u003cli data-start=\"1989\" data-end=\"2001\"\u003e\u003cp data-start=\"1991\" data-end=\"2001\"\u003eovervoltage\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2002\" data-end=\"2014\"\u003e\u003cp data-start=\"2004\" data-end=\"2014\"\u003eundervoltage\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2015\" data-end=\"2032\"\u003e\u003cp data-start=\"2017\" data-end=\"2032\"\u003ephase failure\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2033\" data-end=\"2059\"\u003e\u003cp data-start=\"2035\" data-end=\"2059\"\u003eincorrect phase sequence\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2087\"\u003e\u003cp data-start=\"2062\" data-end=\"2087\"\u003eLoss of neutral conductor\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2094\" data-end=\"2120\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"2097\" data-end=\"2120\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIMPORTANT NOTICE\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"2122\" data-end=\"2267\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cspan data-start=\"2125\" data-end=\"2152\" style=\"font-weight: 600;\"\u003eThe relay does NOT regulate the voltage!\u003c\/span\u003e\u003cbr data-start=\"2152\" data-end=\"2155\"\u003eIt is only used for \u003cem data-start=\"2170\" data-end=\"2187\"\u003eload disconnection\u003c\/em\u003e in dangerous network conditions, not for stabilizing or compensating voltage.\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Yes","offer_id":51204693623112,"sku":"GKM-02F","price":46.97,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":51204693655880,"sku":"GKM-02","price":24.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/file_584a5443-e4a0-48ab-978c-c76c636aa476.webp?v=1755799893","url":"https:\/\/pelek-de.com\/en\/products\/dreiphasiges-uberwachungs-schutzrelais-fur-uberspannung-unterspannung-folge-fehlersteuerung-2","provider":"Deutschland Pelek","version":"1.0","type":"link"}