{"product_id":"dj-v96t-schalttafeleinbau-dreiphasen-digitalvoltmeter-fur-ac","title":"DJ-V96T Panel Mount Three-Phase Digital Voltmeter for AC","description":"\u003ch1 data-start=\"129\" data-end=\"186\"\u003e\u003cstrong data-start=\"131\" data-end=\"186\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eThree-phase digital panel voltmeter TENSE DJ-V96T\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp data-start=\"188\" data-end=\"515\"\u003e\u003cstrong data-start=\"188\" data-end=\"207\"\u003eProduct description:\u003c\/strong\u003e\u003cbr data-start=\"207\" data-end=\"210\"\u003e\nThe digital panel voltage meter DJ-V96T is designed for the \u003cstrong data-start=\"259\" data-end=\"301\"\u003esimultaneous measurement of voltage on three phases of\u003c\/strong\u003e alternating current. It can monitor voltages from phase to neutral (L-N) as well as from phase to phase (L-L) and also displays the \u003cstrong data-start=\"422\" data-end=\"442\"\u003ephase sequence\u003c\/strong\u003e. The display mode is selected with the \u003cstrong data-start=\"484\" data-end=\"494\"\u003eSELECT button\u003c\/strong\u003e on the front panel.\u003c\/p\u003e\n\u003cp data-start=\"517\" data-end=\"540\"\u003e\u003cstrong data-start=\"517\" data-end=\"538\"\u003eOperating principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"541\" data-end=\"875\"\u003e\n\u003cli data-start=\"541\" data-end=\"611\"\u003e\n\u003cp data-start=\"543\" data-end=\"611\"\u003eDisplays the voltage at the inputs \u003cstrong data-start=\"594\" data-end=\"608\"\u003eL1, L2, L3\u003c\/strong\u003e when the power supply is on.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"612\" data-end=\"731\"\u003e\n\u003cp data-start=\"614\" data-end=\"731\"\u003ePressing the SELECT button switches the display to the \u003cstrong data-start=\"662\" data-end=\"693\"\u003ephase voltages L12, L23, L31\u003c\/strong\u003e and then to the \u003cstrong data-start=\"708\" data-end=\"728\"\u003ephase sequence\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"732\" data-end=\"875\"\u003e\n\u003cp data-start=\"734\" data-end=\"875\"\u003eThe display of \u003cstrong data-start=\"749\" data-end=\"763\"\u003eL1, L2, L3\u003c\/strong\u003e from top to bottom indicates the correct phase sequence; the display \u003cstrong data-start=\"822\" data-end=\"836\"\u003eL1, L3, L2\u003c\/strong\u003e indicates the incorrect phase sequence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"877\" data-end=\"905\"\u003e\u003cstrong data-start=\"877\" data-end=\"903\"\u003e\u003cfont style=\"font-size: 16px;\"\u003eTechnical data:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp data-start=\"877\" data-end=\"905\"\u003e\u003cstrong data-start=\"877\" data-end=\"903\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage (Un)\u003c\/td\u003e\n\u003ctd\u003e140-300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C ... +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range L-N\u003c\/td\u003e\n\u003ctd\u003e5-300 V AC (min. 140 V at L1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range L-L\u003c\/td\u003e\n\u003ctd\u003e5-500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3×3 digits, height 14 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting opening dimensions\u003c\/td\u003e\n\u003ctd\u003e91×91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection type\u003c\/td\u003e\n\u003ctd\u003ePlug-in connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e≤300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable diameter\u003c\/td\u003e\n\u003ctd\u003e1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eOn the front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"1447\" data-end=\"1461\"\u003e\u003cstrong data-start=\"1447\" data-end=\"1459\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp data-start=\"1447\" data-end=\"1461\"\u003e\u003cstrong data-start=\"1447\" data-end=\"1459\"\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1462\" data-end=\"1633\"\u003e\n\u003cli data-start=\"1462\" data-end=\"1524\"\u003e\n\u003cp data-start=\"1464\" data-end=\"1524\"\u003eVoltage monitoring in \u003cstrong data-start=\"1484\" data-end=\"1522\"\u003ethree-phase electrical distribution systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1525\" data-end=\"1557\"\u003e\n\u003cp data-start=\"1527\" data-end=\"1557\"\u003eMonitoring of \u003cstrong data-start=\"1536\" data-end=\"1555\"\u003ephase sequence\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1558\" data-end=\"1633\"\u003e\n\u003cp data-start=\"1560\" data-end=\"1633\"\u003e\u003cstrong data-start=\"1573\" data-end=\"1593\"\u003eL-N and L-L voltage monitoring\u003c\/strong\u003e in industrial and residential installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1635\" data-end=\"1648\"\u003e\u003cstrong data-start=\"1635\" data-end=\"1646\"\u003eAdvantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1649\" data-end=\"1806\"\u003e\n\u003cli data-start=\"1649\" data-end=\"1704\"\u003e\n\u003cp data-start=\"1651\" data-end=\"1704\"\u003eClear and accurate voltage display on all phases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1705\" data-end=\"1751\"\u003e\n\u003cp data-start=\"1707\" data-end=\"1751\"\u003eEasy switching between display modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1752\" data-end=\"1806\"\u003e\n\u003cp data-start=\"1754\" data-end=\"1806\"\u003eQuick installation in a standard panel (91×91 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204708598088,"sku":"DJ-V96T","price":48.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/1f424cf88494a6e470d8673076c8159d.png?v=1755800351","url":"https:\/\/pelek-de.com\/en\/products\/dj-v96t-schalttafeleinbau-dreiphasen-digitalvoltmeter-fur-ac","provider":"Deutschland Pelek","version":"1.0","type":"link"}