{"product_id":"digitales-uberstromrelais-mit-uberspannungsschutz-trm-30m","title":"Digital overcurrent relay with overvoltage protection TRM-30M","description":"\u003ch1 data-start=\"67\" data-end=\"154\"\u003e\u003cstrong data-start=\"69\" data-end=\"154\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eCurrent and voltage monitoring relay TRM-30M - single-phase, 30 A, digital display\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"156\" data-end=\"179\"\u003e\u003cstrong data-start=\"159\" data-end=\"177\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"180\" data-end=\"491\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe TRM-30M is a \u003cstrong data-start=\"191\" data-end=\"221\"\u003esingle-phase digital relay\u003c\/strong\u003e for protecting sensitive devices against \u003cstrong data-start=\"263\" data-end=\"298\"\u003eovercurrent, overvoltage, and undervoltage\u003c\/strong\u003e.\u003cbr data-start=\"299\" data-end=\"302\"\u003eThe device allows precise adjustment of \u003cstrong data-start=\"337\" data-end=\"369\"\u003ecurrent limit and delay\u003c\/strong\u003e and displays the measured \u003cstrong data-start=\"397\" data-end=\"416\"\u003evoltage and current values\u003c\/strong\u003e on a two-line display. A \u003cstrong data-start=\"462\" data-end=\"488\"\u003ecurrent transformer\u003c\/strong\u003e is included.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"498\" data-end=\"518\"\u003e\u003cstrong data-start=\"501\" data-end=\"518\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"519\" data-end=\"955\"\u003e\n\u003cli data-start=\"519\" data-end=\"577\"\u003e\n\u003cp data-start=\"521\" data-end=\"577\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOverload protection: adjustable current 0.5 ... 30 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"578\" data-end=\"650\"\u003e\n\u003cp data-start=\"580\" data-end=\"650\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOvervoltage protection: activation at voltage \u0026gt; 250 V (fixed)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"651\" data-end=\"723\"\u003e\n\u003cp data-start=\"653\" data-end=\"723\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUndervoltage protection: activation at voltage \u0026lt; 150 V (fixed)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"724\" data-end=\"749\"\u003e\n\u003cp data-start=\"726\" data-end=\"749\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eVoltage hysteresis: 5 V\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"750\" data-end=\"780\"\u003e\n\u003cp data-start=\"752\" data-end=\"780\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eVoltage fault delay: 2 s\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"781\" data-end=\"808\"\u003e\n\u003cp data-start=\"783\" data-end=\"808\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eVoltage fault reset: 2 s\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"809\" data-end=\"926\"\u003e\n\u003cp data-start=\"811\" data-end=\"847\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eClear two-line LED display:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"850\" data-end=\"926\"\u003e\n\u003cli data-start=\"850\" data-end=\"885\"\u003e\n\u003cp data-start=\"852\" data-end=\"885\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUpper line - voltage and overcurrent\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"888\" data-end=\"926\"\u003e\n\u003cp data-start=\"890\" data-end=\"926\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLower line - delay time and current\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"927\" data-end=\"955\"\u003e\n\u003cp data-start=\"929\" data-end=\"955\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLED status indicator \"OUT\"\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"962\" data-end=\"985\"\u003e\u003cstrong data-start=\"965\" data-end=\"985\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating principle\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"986\" data-end=\"1335\"\u003e\n\u003cli data-start=\"986\" data-end=\"1066\"\u003e\n\u003cp data-start=\"988\" data-end=\"1066\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen the power is switched on, the set overcurrent value and delay time are displayed.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1067\" data-end=\"1155\"\u003e\n\u003cp data-start=\"1069\" data-end=\"1155\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe device monitors the voltage between phase and neutral and the current drawn from the network.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1156\" data-end=\"1335\"\u003e\n\u003cp data-start=\"1158\" data-end=\"1235\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the set values are exceeded, the relay switches to a \u003cstrong data-start=\"1213\" data-end=\"1232\"\u003efault state\u003c\/strong\u003e:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1238\" data-end=\"1335\"\u003e\n\u003cli data-start=\"1238\" data-end=\"1282\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1282\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eNO contact open, NC contact closed\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1305\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1305\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe LED \"OUT\" goes off\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1308\" data-end=\"1335\"\u003e\n\u003cp data-start=\"1310\" data-end=\"1335\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe corresponding indicator blinks\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1342\" data-end=\"1364\"\u003e\u003cstrong data-start=\"1345\" data-end=\"1364\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtection functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1365\" data-end=\"1607\"\u003e\n\u003cli data-start=\"1365\" data-end=\"1447\"\u003e\n\u003cp data-start=\"1367\" data-end=\"1447\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1367\" data-end=\"1392\"\u003eOverload (overcurrent):\u003c\/strong\u003e when the set current and time delay are exceeded\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1527\"\u003e\n\u003cp data-start=\"1450\" data-end=\"1527\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1450\" data-end=\"1462\"\u003eOvervoltage:\u003c\/strong\u003e at a voltage above 250 V (automatic reset when voltage falls below 245 V)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1528\" data-end=\"1607\"\u003e\n\u003cp data-start=\"1530\" data-end=\"1607\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1530\" data-end=\"1542\"\u003eUndervoltage:\u003c\/strong\u003e at a voltage below 150 V (automatic reset after rising above 155 V)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1614\" data-end=\"1632\"\u003e\u003cstrong data-start=\"1617\" data-end=\"1632\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSignaling\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1633\" data-end=\"1780\"\u003e\n\u003cli data-start=\"1633\" data-end=\"1692\"\u003e\n\u003cp data-start=\"1635\" data-end=\"1692\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUpper indicator blinks: high or low voltage fault\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1693\" data-end=\"1739\"\u003e\n\u003cp data-start=\"1695\" data-end=\"1739\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLower indicator blinks: high current fault\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1740\" data-end=\"1780\"\u003e\n\u003cp data-start=\"1742\" data-end=\"1780\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLED OUT: lights up during normal operation\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1787\" data-end=\"1803\"\u003e\u003cstrong data-start=\"1790\" data-end=\"1803\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelay status\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\u003cdiv tabindex=\"-1\" class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\"\u003e\u003ctable data-start=\"1804\" data-end=\"2029\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1804\" data-end=\"1847\"\u003e\u003ctr data-start=\"1804\" data-end=\"1847\"\u003e\n\u003cth data-start=\"1804\" data-end=\"1820\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDevice status\u003c\/font\u003e\u003c\/th\u003e\n\u003cth data-start=\"1820\" data-end=\"1833\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eNO contact\u003c\/font\u003e\u003c\/th\u003e\n\u003cth data-start=\"1833\" data-end=\"1847\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eNC contact\u003c\/font\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody data-start=\"1892\" data-end=\"2029\"\u003e\n\u003ctr data-start=\"1892\" data-end=\"1935\"\u003e\n\u003ctd data-start=\"1892\" data-end=\"1908\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eNo voltage\u003c\/font\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1908\" data-end=\"1921\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOpen\u003c\/font\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1921\" data-end=\"1935\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSwitched off\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1936\" data-end=\"1980\"\u003e\n\u003ctd data-start=\"1936\" data-end=\"1957\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eVoltage, fault\u003c\/font\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1957\" data-end=\"1969\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOpen\u003c\/font\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1969\" data-end=\"1980\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSwitched off\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1981\" data-end=\"2029\"\u003e\n\u003ctd data-start=\"1981\" data-end=\"2006\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLive, no fault\u003c\/font\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2006\" data-end=\"2016\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisconnected\u003c\/font\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2016\" data-end=\"2029\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSwitched off\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch2 data-start=\"2036\" data-end=\"2050\"\u003e\u003cstrong data-start=\"2039\" data-end=\"2050\" style=\"font-family: inherit;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUsage\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2051\" data-end=\"2265\"\u003e\n\u003cli data-start=\"2051\" data-end=\"2125\"\u003e\n\u003cp data-start=\"2053\" data-end=\"2125\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtection of single-phase sensitive devices (motors, heaters, lighting)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2126\" data-end=\"2195\"\u003e\n\u003cp data-start=\"2128\" data-end=\"2195\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCurrent and voltage monitoring in industrial and domestic applications\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2196\" data-end=\"2265\"\u003e\n\u003cp data-start=\"2198\" data-end=\"2265\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePrecise limit and time delay settings for reliable operation\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204660363592,"sku":"TRM-30M","price":51.93,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/1bea46524163a74db8b8805646b09c3a.png?v=1755799042","url":"https:\/\/pelek-de.com\/en\/products\/digitales-uberstromrelais-mit-uberspannungsschutz-trm-30m","provider":"Deutschland Pelek","version":"1.0","type":"link"}