{"product_id":"digitaler-stromanzeiger-dreiphasen-panel-amperemeter-dreiphasig-eingebaut","title":"Digital Current Indicator Three-Phase Panel Ammeter Three-Phase Built-in","description":"\u003ch2 data-start=\"102\" data-end=\"157\"\u003e\u003cstrong data-start=\"105\" data-end=\"157\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eDJ-A96T - Digital three-phase current meter for control panels\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"159\" data-end=\"454\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe three-phase digital ammeter DJ-A96T is designed for accurate current monitoring in three-phase systems. It can display the instantaneous load of each phase \u003cstrong data-start=\"318\" data-end=\"332\"\u003eL1, L2, L3\u003c\/strong\u003e using external current transformers (CT). The device offers a clear display, easy setup, and reliable operation.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"461\" data-end=\"485\"\u003e\u003cstrong data-start=\"464\" data-end=\"485\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"486\" data-end=\"761\"\u003e\n\u003cli data-start=\"486\" data-end=\"528\"\u003e\n\u003cp data-start=\"488\" data-end=\"528\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCurrent measurement in three-phase systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"529\" data-end=\"572\"\u003e\n\u003cp data-start=\"531\" data-end=\"572\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSeparate display for the phases \u003cstrong data-start=\"556\" data-end=\"570\"\u003eL1, L2, L3\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"573\" data-end=\"626\"\u003e\n\u003cp data-start=\"575\" data-end=\"626\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement with external current transformers\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"627\" data-end=\"669\"\u003e\n\u003cp data-start=\"629\" data-end=\"669\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEasy setting of the current transformer ratio\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"670\" data-end=\"728\"\u003e\n\u003cp data-start=\"672\" data-end=\"728\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLarge and easy-to-read display - \u003cstrong data-start=\"698\" data-end=\"713\"\u003e3×4 digits\u003c\/strong\u003e, height 14 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"729\" data-end=\"761\"\u003e\n\u003cp data-start=\"731\" data-end=\"761\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCompact design of the control panel\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"768\" data-end=\"805\"\u003e\u003cstrong data-start=\"771\" data-end=\"805\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical parameters of the ammeter\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"806\" data-end=\"1207\"\u003e\n\u003cli data-start=\"806\" data-end=\"839\"\u003e\n\u003cp data-start=\"808\" data-end=\"839\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"808\" data-end=\"828\"\u003eSupply voltage:\u003c\/strong\u003e 230 V AC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"840\" data-end=\"873\"\u003e\n\u003cp data-start=\"842\" data-end=\"873\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"842\" data-end=\"864\"\u003eDevice consumption:\u003c\/strong\u003e \u0026lt; 4 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"874\" data-end=\"913\"\u003e\n\u003cp data-start=\"876\" data-end=\"913\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"876\" data-end=\"901\"\u003eCurrent measurement range:\u003c\/strong\u003e 0.1...5.5 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"914\" data-end=\"962\"\u003e\n\u003cp data-start=\"916\" data-end=\"962\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"916\" data-end=\"942\"\u003eSupported current transformer range:\u003c\/strong\u003e 5\/5 A to 5000\/5 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"963\" data-end=\"992\"\u003e\n\u003cp data-start=\"965\" data-end=\"992\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"965\" data-end=\"985\"\u003eMeasurement accuracy:\u003c\/strong\u003e ±2%\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"993\" data-end=\"1039\"\u003e\n\u003cp data-start=\"995\" data-end=\"1039\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"995\" data-end=\"1007\"\u003eDisplay:\u003c\/strong\u003e LED, 3×4 digits, height 14 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1040\" data-end=\"1071\"\u003e\n\u003cp data-start=\"1042\" data-end=\"1071\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1042\" data-end=\"1054\"\u003eDimensions:\u003c\/strong\u003e 97,2 × 97,2 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1072\" data-end=\"1108\"\u003e\n\u003cp data-start=\"1074\" data-end=\"1108\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1074\" data-end=\"1095\"\u003eCutout size:\u003c\/strong\u003e 91 × 91 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1109\" data-end=\"1131\"\u003e\n\u003cp data-start=\"1111\" data-end=\"1131\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1111\" data-end=\"1123\"\u003eDepth:\u003c\/strong\u003e 45 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1132\" data-end=\"1207\"\u003e\n\u003cp data-start=\"1134\" data-end=\"1207\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1134\" data-end=\"1179\"\u003eCurrent transformers are not included in the delivery\u003c\/strong\u003e (can be purchased separately)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1214\" data-end=\"1249\"\u003e\u003cstrong data-start=\"1217\" data-end=\"1249\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFunctionality and Settings\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003col data-start=\"1250\" data-end=\"1739\"\u003e\n\u003cli data-start=\"1250\" data-end=\"1297\"\u003e\n\u003cp data-start=\"1253\" data-end=\"1297\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnect the device according to the wiring diagram.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1298\" data-end=\"1390\"\u003e\n\u003cp data-start=\"1301\" data-end=\"1390\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnect the current transformers according to the expected current in the system (conversion xxxx\/5 A).\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1391\" data-end=\"1480\"\u003e\n\u003cp data-start=\"1394\" data-end=\"1480\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnect the current transformer wires to the terminals \u003cstrong data-start=\"1424\" data-end=\"1432\"\u003e\"kx\"\u003c\/strong\u003e and \u003cstrong data-start=\"1435\" data-end=\"1443\"\u003e\"lx\".\u003c\/strong\u003e The current transformer output must not exceed 5 A.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1481\" data-end=\"1544\"\u003e\n\u003cp data-start=\"1484\" data-end=\"1544\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAfter turning on the power supply, press and hold the \u003cstrong data-start=\"1521\" data-end=\"1531\"\u003e\"Menu\"\u003c\/strong\u003e button for 2 seconds.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1545\" data-end=\"1613\"\u003e\n\u003cp data-start=\"1548\" data-end=\"1613\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUse the \u003cstrong data-start=\"1564\" data-end=\"1581\"\u003eUp\/Down\u003c\/strong\u003e buttons to adjust the conversion of the current transformers used.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1614\" data-end=\"1672\"\u003e\n\u003cp data-start=\"1617\" data-end=\"1672\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSave the settings by pressing and holding the \u003cstrong data-start=\"1659\" data-end=\"1669\"\u003e\"Menu\" button.\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1673\" data-end=\"1739\"\u003e\n\u003cp data-start=\"1676\" data-end=\"1739\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen the load is connected, the ammeter begins to measure and display the current.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cblockquote data-start=\"1741\" data-end=\"1830\"\u003e\n\u003cfont style=\"font-size: 14px;\"\u003e\n\u003c\/font\u003e\u003cp data-start=\"1743\" data-end=\"1830\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1743\" data-end=\"1758\"\u003eNote:\u003c\/strong\u003e Current transformers must always be grounded for safety reasons.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 data-start=\"1837\" data-end=\"1895\"\u003e\u003cstrong data-start=\"1840\" data-end=\"1895\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical features of the semiconductor output relay\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1896\" data-end=\"1983\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e(This time the listed parameters refer to the semiconductor relay - if it should be separate, I can split it).\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1985\" data-end=\"2362\"\u003e\n\u003cli data-start=\"1985\" data-end=\"2015\"\u003e\n\u003cp data-start=\"1987\" data-end=\"2015\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1987\" data-end=\"2000\"\u003eRelay type:\u003c\/strong\u003e Semiconductor\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2016\" data-end=\"2056\"\u003e\n\u003cp data-start=\"2018\" data-end=\"2056\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2018\" data-end=\"2044\"\u003eControl voltage (input):\u003c\/strong\u003e 3...32 V DC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2057\" data-end=\"2114\"\u003e\n\u003cp data-start=\"2059\" data-end=\"2114\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2059\" data-end=\"2078\"\u003eSwitching voltage:\u003c\/strong\u003e 24...480 V AC (not suitable for motors)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2115\" data-end=\"2155\"\u003e\n\u003cp data-start=\"2117\" data-end=\"2155\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2117\" data-end=\"2147\"\u003eSwitching voltage drop:\u003c\/strong\u003e \u0026lt; 3 V\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2156\" data-end=\"2185\"\u003e\n\u003cp data-start=\"2158\" data-end=\"2185\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2158\" data-end=\"2178\"\u003eTrigger current:\u003c\/strong\u003e 5 mA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2186\" data-end=\"2217\"\u003e\n\u003cp data-start=\"2188\" data-end=\"2217\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2188\" data-end=\"2205\"\u003eCoil voltage:\u003c\/strong\u003e 3...32 V DC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2218\" data-end=\"2255\"\u003e\n\u003cp data-start=\"2220\" data-end=\"2255\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2220\" data-end=\"2248\"\u003eMaximum switching current:\u003c\/strong\u003e 25 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2256\" data-end=\"2291\"\u003e\n\u003cp data-start=\"2258\" data-end=\"2291\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2258\" data-end=\"2279\"\u003eInsulation resistance:\u003c\/strong\u003e 2500 V AC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2292\" data-end=\"2362\"\u003e\n\u003cp data-start=\"2294\" data-end=\"2362\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2294\" data-end=\"2313\"\u003eSwitching method:\u003c\/strong\u003e Turn on at zero crossing current\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204708794696,"sku":"DJ-A96T","price":43.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/5668b11ced30e9727cdcb5355cff5330.png?v=1755800359","url":"https:\/\/pelek-de.com\/en\/products\/digitaler-stromanzeiger-dreiphasen-panel-amperemeter-dreiphasig-eingebaut","provider":"Deutschland Pelek","version":"1.0","type":"link"}