{"product_id":"dav-72d-digitales-strom-und-spannungsmessgerat-fur-ac-100-ampere-150v-fur-schaltschrankmontage","title":"DAV-72D Digital current and voltage meter for AC 100 Ampere, 150V for control panel mounting","description":"\u003cdiv\u003e\n\u003ch1 data-start=\"105\" data-end=\"166\"\u003e\u003cstrong data-start=\"107\" data-end=\"166\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eDigital panel multimeter 72x72 mm - TENSE (DAV-72D)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp data-start=\"168\" data-end=\"561\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"168\" data-end=\"187\"\u003eProduct description:\u003c\/strong\u003e\u003cbr data-start=\"187\" data-end=\"190\"\u003eThe DAV-72D is a single-phase digital combined voltmeter-ammeter designed for continuous monitoring of the AC voltage between phase and neutral conductor and the load current drawn, measured by an external current transformer (CT-120, included). The device is suitable for electrical switchboards, production plants, and energy distribution or monitoring systems.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"568\" data-end=\"602\"\u003e\u003cstrong data-start=\"571\" data-end=\"602\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating principle and application:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"603\" data-end=\"919\"\u003e\n\u003cli data-start=\"603\" data-end=\"679\"\u003e\n\u003cp data-start=\"605\" data-end=\"679\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnection to the phase and neutral conductor to be measured via the voltage measurement terminals.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"680\" data-end=\"821\"\u003e\n\u003cp data-start=\"682\" data-end=\"821\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCurrent measurement via an external current transformer CT-120, whose secondary conductor is connected to terminals K and L on the back of the device.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"822\" data-end=\"919\"\u003e\n\u003cp data-start=\"824\" data-end=\"859\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen voltage is applied, the following is displayed:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"862\" data-end=\"919\"\u003e\n\u003cli data-start=\"862\" data-end=\"892\"\u003e\n\u003cp data-start=\"864\" data-end=\"892\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eActual phase voltage (V)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"895\" data-end=\"919\"\u003e\n\u003cp data-start=\"897\" data-end=\"919\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLoad current (A)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"921\" data-end=\"949\"\u003e\u003cstrong data-start=\"921\" data-end=\"947\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eInstallation and setup:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"950\" data-end=\"1161\"\u003e\n\u003cli data-start=\"950\" data-end=\"995\"\u003e\n\u003cp data-start=\"952\" data-end=\"995\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFront panel mounting (cutout 68 × 68 mm)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"996\" data-end=\"1071\"\u003e\n\u003cp data-start=\"998\" data-end=\"1071\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWiring of the CT-120 as shown in the diagram, load conductor routed through the transformer\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1072\" data-end=\"1161\"\u003e\n\u003cp data-start=\"1074\" data-end=\"1161\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eNo other current transformers may be used - the device is specially calibrated for the CT-120.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1168\" data-end=\"1197\"\u003e\u003cstrong data-start=\"1171\" data-end=\"1197\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1198\" data-end=\"1713\"\u003e\n\u003cli data-start=\"1198\" data-end=\"1235\"\u003e\n\u003cp data-start=\"1200\" data-end=\"1235\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1200\" data-end=\"1220\"\u003eOperating voltage:\u003c\/strong\u003e 140-270 VAC.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1236\" data-end=\"1270\"\u003e\n\u003cp data-start=\"1238\" data-end=\"1270\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1238\" data-end=\"1259\"\u003eMains frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1271\" data-end=\"1316\"\u003e\n\u003cp data-start=\"1273\" data-end=\"1316\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1273\" data-end=\"1303\"\u003eDisplayed voltage range:\u003c\/strong\u003e 5-300 V AC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1317\" data-end=\"1368\"\u003e\n\u003cp data-start=\"1319\" data-end=\"1368\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1319\" data-end=\"1344\"\u003eMeasured current range:\u003c\/strong\u003e 1-100 A (via CT-120)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1369\" data-end=\"1423\"\u003e\n\u003cp data-start=\"1371\" data-end=\"1386\"\u003e\u003cstrong data-start=\"1371\" data-end=\"1384\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement accuracy:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1389\" data-end=\"1423\"\u003e\n\u003cli data-start=\"1389\" data-end=\"1405\"\u003e\n\u003cp data-start=\"1391\" data-end=\"1405\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eVoltage: ±1%\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1408\" data-end=\"1423\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1423\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCurrent: ±3 %\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1424\" data-end=\"1482\"\u003e\n\u003cp data-start=\"1426\" data-end=\"1482\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1426\" data-end=\"1438\"\u003eDisplay:\u003c\/strong\u003e 2 lines, 3 digits, character height 14 mm\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1483\" data-end=\"1513\"\u003e\n\u003cp data-start=\"1485\" data-end=\"1513\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1485\" data-end=\"1505\"\u003eDevice power:\u003c\/strong\u003e \u0026lt;6 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1514\" data-end=\"1556\"\u003e\n\u003cp data-start=\"1516\" data-end=\"1556\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1516\" data-end=\"1537\"\u003eOperating temperature:\u003c\/strong\u003e -20 °C to +55 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1557\" data-end=\"1591\"\u003e\n\u003cp data-start=\"1559\" data-end=\"1591\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1559\" data-end=\"1579\"\u003eAltitude:\u003c\/strong\u003e up to 2000 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1592\" data-end=\"1651\"\u003e\n\u003cp data-start=\"1594\" data-end=\"1651\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1594\" data-end=\"1608\"\u003eConnection:\u003c\/strong\u003e pluggable terminals, cable cross-section up to 1.5 mm²\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1652\" data-end=\"1686\"\u003e\n\u003cp data-start=\"1654\" data-end=\"1686\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1654\" data-end=\"1665\"\u003eMounting:\u003c\/strong\u003e switchboard, front side\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1687\" data-end=\"1713\"\u003e\n\u003cp data-start=\"1689\" data-end=\"1713\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1689\" data-end=\"1702\" style=\"\"\u003eWeight:\u003c\/strong\u003e up to 220 g\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204708172104,"sku":"DAV-72D","price":20.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/e74b598f2e65db8830704264ab52851c.png?v=1755800342","url":"https:\/\/pelek-de.com\/en\/products\/dav-72d-digitales-strom-und-spannungsmessgerat-fur-ac-100-ampere-150v-fur-schaltschrankmontage","provider":"Deutschland Pelek","version":"1.0","type":"link"}