{"product_id":"brunnenfullstandsmesser-regler-fur-einphasenpumpe-din-30a","title":"Well level gauge \/ controller for single-phase pump DIN 30A","description":"\u003cdiv\u003e\n\u003ch1 data-start=\"116\" data-end=\"203\"\u003e\u003cstrong data-start=\"118\" data-end=\"203\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eTENSE MDK-03 single-phase submersible pump controller, 150-270 V AC, 30 A\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"205\" data-end=\"226\"\u003e\u003cstrong data-start=\"208\" data-end=\"226\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"227\" data-end=\"363\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe TENSE MDK-03 control unit is designed for the \u003cstrong data-start=\"272\" data-end=\"325\"\u003eprotection and control of single-phase submersible pumps\u003c\/strong\u003e up to 4 kW.\u003cbr data-start=\"334\" data-end=\"337\"\u003eIt provides protection against:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"364\" data-end=\"460\"\u003e\n\u003cli data-start=\"364\" data-end=\"385\"\u003e\n\u003cp data-start=\"366\" data-end=\"385\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOvervoltage and undervoltage\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"386\" data-end=\"420\"\u003e\n\u003cp data-start=\"388\" data-end=\"420\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOvercurrent and overload of the pump\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"421\" data-end=\"460\"\u003e\n\u003cp data-start=\"423\" data-end=\"460\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWater shortage in the well or borehole\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"462\" data-end=\"625\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eBuilt-in functions allow monitoring of tank fill level, \u003cstrong data-start=\"514\" data-end=\"545\"\u003esetting of time delays\u003c\/strong\u003e, control of the start interval, and the ability to \u003cstrong data-start=\"584\" data-end=\"624\"\u003eremotely turn the pump on and off\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"632\" data-end=\"657\"\u003e\u003cstrong data-start=\"635\" data-end=\"657\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"658\" data-end=\"1224\"\u003e\n\u003cli data-start=\"658\" data-end=\"703\"\u003e\n\u003cp data-start=\"660\" data-end=\"703\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSingle-phase power supply: 150-270 VAC, 50 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"704\" data-end=\"724\"\u003e\n\u003cp data-start=\"706\" data-end=\"724\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMax. current: 30 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"725\" data-end=\"814\"\u003e\n\u003cp data-start=\"727\" data-end=\"814\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMicroprocessor control with LED display for voltage, current, and electrode status\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"815\" data-end=\"895\"\u003e\n\u003cp data-start=\"817\" data-end=\"895\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtection functions: overvoltage, undervoltage, overcurrent, undercurrent, water level control\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"896\" data-end=\"1052\"\u003e\n\u003cp data-start=\"898\" data-end=\"1052\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdjustable operating parameters: P1-P12 (e.g., voltage, current, response delay, start intervals, number of automatic resets, upper sensor delay)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1053\" data-end=\"1085\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1085\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating modes: START \/ STOP\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1086\" data-end=\"1135\"\u003e\n\u003cp data-start=\"1088\" data-end=\"1135\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eStorage of the last device state before shutdown\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1136\" data-end=\"1224\"\u003e\n\u003cp data-start=\"1138\" data-end=\"1224\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of electrode immersion in water (upper - red indicator, lower - yellow indicator)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1231\" data-end=\"1257\"\u003e\u003cstrong data-start=\"1234\" data-end=\"1257\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1258\" data-end=\"1629\"\u003e\n\u003cli data-start=\"1258\" data-end=\"1295\"\u003e\n\u003cp data-start=\"1260\" data-end=\"1295\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1260\" data-end=\"1280\"\u003eOperating voltage:\u003c\/strong\u003e 150-270 V AC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1296\" data-end=\"1320\"\u003e\n\u003cp data-start=\"1298\" data-end=\"1320\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1298\" data-end=\"1312\"\u003eFrequency:\u003c\/strong\u003e 50 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1321\" data-end=\"1350\"\u003e\n\u003cp data-start=\"1323\" data-end=\"1350\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1323\" data-end=\"1341\"\u003eCurrent range:\u003c\/strong\u003e 1-30 A\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1351\" data-end=\"1382\"\u003e\n\u003cp data-start=\"1353\" data-end=\"1382\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1353\" data-end=\"1374\"\u003ePower consumption:\u003c\/strong\u003e \u0026lt; 6 W\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1383\" data-end=\"1421\"\u003e\n\u003cp data-start=\"1385\" data-end=\"1421\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1385\" data-end=\"1411\"\u003eLiquid sensitivity:\u003c\/strong\u003e \u0026lt; 50 kΩ\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1422\" data-end=\"1449\"\u003e\n\u003cp data-start=\"1424\" data-end=\"1449\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1424\" data-end=\"1442\"\u003eProtection class:\u003c\/strong\u003e IP20\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1492\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1492\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1473\"\u003eOperating temperature:\u003c\/strong\u003e -20 °C to +55 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1493\" data-end=\"1560\"\u003e\n\u003cp data-start=\"1495\" data-end=\"1560\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1495\" data-end=\"1513\"\u003eCable cross-section:\u003c\/strong\u003e Max. 10 mm² (power supply), electrodes up to 2.5 mm²\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1561\" data-end=\"1586\"\u003e\n\u003cp data-start=\"1563\" data-end=\"1586\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1563\" data-end=\"1576\"\u003eWeight:\u003c\/strong\u003e 0.25 kg\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1587\" data-end=\"1629\"\u003e\n\u003cp data-start=\"1589\" data-end=\"1629\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1589\" data-end=\"1618\"\u003eInstallation height\u003c\/strong\u003e: \u0026lt; 2000 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1636\" data-end=\"1650\"\u003e\u003cstrong data-start=\"1639\" data-end=\"1650\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1651\" data-end=\"1849\"\u003e\n\u003cli data-start=\"1651\" data-end=\"1714\"\u003e\n\u003cp data-start=\"1653\" data-end=\"1714\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtection of submersible pumps against dry running and overload\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1715\" data-end=\"1763\"\u003e\n\u003cp data-start=\"1717\" data-end=\"1763\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWater level control in wells and tanks\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1764\" data-end=\"1808\"\u003e\n\u003cp data-start=\"1766\" data-end=\"1808\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eReal-time monitoring of voltage and current\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1809\" data-end=\"1849\"\u003e\n\u003cp data-start=\"1811\" data-end=\"1849\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRemote on and off control of the pump\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1856\" data-end=\"1882\"\u003e\u003cstrong data-start=\"1859\" data-end=\"1882\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eImportant notes\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1883\" data-end=\"2248\"\u003e\n\u003cli data-start=\"1883\" data-end=\"1975\"\u003e\n\u003cp data-start=\"1885\" data-end=\"1975\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1885\" data-end=\"1945\"\u003eElectrodes \/ water level sensors are not included\u003c\/strong\u003e - must be ordered separately\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1976\" data-end=\"2034\"\u003e\n\u003cp data-start=\"1978\" data-end=\"2034\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe control unit must be \u003cstrong data-start=\"1997\" data-end=\"2032\"\u003econnected according to the manufacturer's wiring diagram\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2035\" data-end=\"2077\"\u003e\n\u003cp data-start=\"2037\" data-end=\"2077\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe liquid must not be flammable or explosive\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2078\" data-end=\"2115\"\u003e\n\u003cp data-start=\"2080\" data-end=\"2115\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe installation temperature must be \u0026gt; 0 °C.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2116\" data-end=\"2146\"\u003e\n\u003cp data-start=\"2118\" data-end=\"2146\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePump must be grounded\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2147\" data-end=\"2248\"\u003e\n\u003cp data-start=\"2149\" data-end=\"2248\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe correct wiring of the inputs for the level relay and remote switch is necessary for the proper operation of the device\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51205741412680,"sku":"MDK-03","price":96.38,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/0809d8808eeba3d0681be7f1cdf23ddf.png?v=1755806817","url":"https:\/\/pelek-de.com\/en\/products\/brunnenfullstandsmesser-regler-fur-einphasenpumpe-din-30a","provider":"Deutschland Pelek","version":"1.0","type":"link"}