{"product_id":"betriebsstundenzahler-digital-mit-lcd-anzeige-230vac","title":"Digital operating hour meter with LCD display 230VAC","description":"\u003ch2 data-start=\"146\" data-end=\"206\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"149\" data-end=\"206\"\u003eOperating hour meter DHM-DIN - DIN rail mounting\u003c\/span\u003e\u003c\/h2\u003e\u003ch3 data-start=\"208\" data-end=\"230\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"212\" data-end=\"230\"\u003eProduct description\u003c\/span\u003e\u003c\/h3\u003e\u003cp data-start=\"231\" data-end=\"532\" style=\"color: rgb(78, 86, 95);\"\u003eThe operating hour meter DHM-DIN is designed to measure the operating time of devices powered by 230 VAC mains voltage. It counts the total time the device is energized - suitable for machines, pumps, fans, compressors, production lines, and generally all devices that require recording of cumulative operating time.\u003c\/p\u003e\u003cp data-start=\"534\" data-end=\"693\" style=\"color: rgb(78, 86, 95);\"\u003eAs soon as 230 VAC voltage is applied, the device automatically starts counting time. The values are displayed on two displays and are also saved during a power failure.\u003c\/p\u003e\u003ch2 data-start=\"700\" data-end=\"728\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"703\" data-end=\"728\"\u003eTechnical data\u003c\/span\u003e\u003c\/h2\u003e\u003cul data-start=\"729\" data-end=\"1276\"\u003e\n\u003cli data-start=\"729\" data-end=\"785\"\u003e\u003cp data-start=\"731\" data-end=\"785\"\u003e\u003cspan data-start=\"731\" data-end=\"751\" style=\"font-weight: 600;\"\u003eSupply voltage:\u003c\/span\u003e 230 VAC (150-260 VAC), 50\/60 Hz\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"786\" data-end=\"808\"\u003e\u003cp data-start=\"788\" data-end=\"808\"\u003e\u003cspan data-start=\"788\" data-end=\"799\" style=\"font-weight: 600;\"\u003ePower consumption:\u003c\/span\u003e \u0026lt; 6 VA\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"809\" data-end=\"856\"\u003e\u003cp data-start=\"811\" data-end=\"856\"\u003e\u003cspan data-start=\"811\" data-end=\"838\" style=\"font-weight: 600;\"\u003eCounting time range:\u003c\/span\u003e up to 99,999 hours\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"857\" data-end=\"1095\"\u003e\n\u003cp data-start=\"859\" data-end=\"875\"\u003e\u003cspan data-start=\"859\" data-end=\"873\" style=\"font-weight: 600;\"\u003eDisplay:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"878\" data-end=\"1095\"\u003e\n\u003cli data-start=\"878\" data-end=\"925\"\u003e\u003cp data-start=\"880\" data-end=\"925\"\u003e2× 3-digit display (digit height 9.2 mm)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"928\" data-end=\"1095\"\u003e\n\u003cp data-start=\"930\" data-end=\"949\"\u003eMode display:\u003c\/p\u003e\n\u003cul data-start=\"954\" data-end=\"1095\"\u003e\n\u003cli data-start=\"954\" data-end=\"998\"\u003e\u003cp data-start=\"956\" data-end=\"998\"\u003eHHH (hours) \/ MM (minutes) \/ S (seconds)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1003\" data-end=\"1095\"\u003e\u003cp data-start=\"1005\" data-end=\"1095\"\u003eAfter exceeding 999 h → lower display shows hours and minutes (see detailed description below)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1096\" data-end=\"1155\"\u003e\u003cp data-start=\"1098\" data-end=\"1155\"\u003e\u003cspan data-start=\"1098\" data-end=\"1109\" style=\"font-weight: 600;\"\u003eMounting:\u003c\/span\u003e MCB (circuit breaker) profile, DIN rail mounting\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1156\" data-end=\"1241\"\u003e\u003cp data-start=\"1158\" data-end=\"1241\"\u003e\u003cspan data-start=\"1158\" data-end=\"1168\" style=\"font-weight: 600;\"\u003eReset:\u003c\/span\u003e RESET button (for DHM-DIN press through RESET hole with non-conductive tool)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1276\"\u003e\u003cp data-start=\"1244\" data-end=\"1276\"\u003e\u003cspan data-start=\"1244\" data-end=\"1256\" style=\"font-weight: 600;\"\u003eDimensions:\u003c\/span\u003e 35.4 × 60 × 90 mm\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1283\" data-end=\"1316\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1286\" data-end=\"1316\"\u003eApplication and operating principle\u003c\/span\u003e\u003c\/h2\u003e\u003col data-start=\"1317\" data-end=\"2008\"\u003e\n\u003cli data-start=\"1317\" data-end=\"1430\"\u003e\u003cp data-start=\"1320\" data-end=\"1430\"\u003e\u003cspan data-start=\"1320\" data-end=\"1348\" style=\"font-weight: 600;\"\u003eConnection according to diagram\u003c\/span\u003e - after applying the supply voltage, the counter automatically starts counting time from zero.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1431\" data-end=\"1647\"\u003e\n\u003cp data-start=\"1434\" data-end=\"1472\"\u003e\u003cspan data-start=\"1434\" data-end=\"1472\" style=\"font-weight: 600;\"\u003eDisplay mode when switched on again:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"1476\" data-end=\"1647\"\u003e\n\u003cli data-start=\"1476\" data-end=\"1522\"\u003e\u003cp data-start=\"1478\" data-end=\"1522\"\u003eUpper display: \u003cspan data-start=\"1493\" data-end=\"1500\" style=\"font-weight: 600;\"\u003eHHH\u003c\/span\u003e - three digits of hours\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1526\" data-end=\"1647\"\u003e\n\u003cp data-start=\"1528\" data-end=\"1596\"\u003eLower display: \u003cspan data-start=\"1543\" data-end=\"1551\" style=\"font-weight: 600;\"\u003eMM S\u003c\/span\u003e - two digits of minutes + one digit of seconds\u003c\/p\u003e\n\u003cul data-start=\"1602\" data-end=\"1647\"\u003e\u003cli data-start=\"1602\" data-end=\"1647\"\u003e\u003cp data-start=\"1604\" data-end=\"1647\"\u003eseconds increase by 1 every \u003cspan data-start=\"1635\" data-end=\"1647\" style=\"font-weight: 600;\"\u003e6 seconds\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1648\" data-end=\"1833\"\u003e\n\u003cp data-start=\"1651\" data-end=\"1679\"\u003e\u003cspan data-start=\"1651\" data-end=\"1679\" style=\"font-weight: 600;\"\u003eAfter exceeding 999 hours:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"1683\" data-end=\"1833\"\u003e\u003cli data-start=\"1683\" data-end=\"1833\"\u003e\n\u003cp data-start=\"1685\" data-end=\"1712\"\u003eThe meaning of the displays changes:\u003c\/p\u003e\n\u003cul data-start=\"1718\" data-end=\"1833\"\u003e\n\u003cli data-start=\"1718\" data-end=\"1748\"\u003e\u003cp data-start=\"1720\" data-end=\"1748\"\u003eLower display → \u003cspan data-start=\"1736\" data-end=\"1746\" style=\"font-weight: 600;\"\u003ehours\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1754\" data-end=\"1833\"\u003e\u003cp data-start=\"1756\" data-end=\"1833\"\u003eright digit of the lower display → \u003cspan data-start=\"1790\" data-end=\"1800\" style=\"font-weight: 600;\"\u003eminutes\u003c\/span\u003e (increases by 1 every 6 minutes)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1834\" data-end=\"2008\"\u003e\n\u003cp data-start=\"1837\" data-end=\"1868\"\u003e\u003cspan data-start=\"1837\" data-end=\"1866\" style=\"font-weight: 600;\"\u003ePower failure memory:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"1872\" data-end=\"2008\"\u003e\n\u003cli data-start=\"1872\" data-end=\"1942\"\u003e\u003cp data-start=\"1874\" data-end=\"1942\"\u003eIf the power supply is interrupted, the device retains the last measured value.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1946\" data-end=\"2008\"\u003e\u003cp data-start=\"1948\" data-end=\"2008\"\u003eWhen switched back on, it continues counting from the stored value\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2 data-start=\"2015\" data-end=\"2042\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"2018\" data-end=\"2042\"\u003eResetting the counter\u003c\/span\u003e\u003c\/h2\u003e\u003cul data-start=\"2043\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2043\" data-end=\"2090\"\u003e\u003cp data-start=\"2045\" data-end=\"2090\"\u003e\u003cspan data-start=\"2045\" data-end=\"2056\" style=\"font-weight: 600;\"\u003eDHM-48:\u003c\/span\u003e Press the RESET button for 5 seconds\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2091\" data-end=\"2190\"\u003e\u003cp data-start=\"2093\" data-end=\"2190\"\u003e\u003cspan data-start=\"2093\" data-end=\"2105\" style=\"font-weight: 600;\"\u003eDHM-DIN:\u003c\/span\u003e Press the concealed RESET button with a non-conductive tool (e.g., an insulated screwdriver)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2191\" data-end=\"2243\"\u003e\u003cp data-start=\"2193\" data-end=\"2243\"\u003eAfter reset, all digits are set to \u003cspan data-start=\"2233\" data-end=\"2243\" style=\"font-weight: 600;\"\u003e000000\u003c\/span\u003e set.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2250\" data-end=\"2272\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"2253\" data-end=\"2272\"\u003eTypical application\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"2273\" data-end=\"2378\" style=\"color: rgb(78, 86, 95);\"\u003eThe counter is used for long-term monitoring of the operation of devices that are switched directly by the supply voltage:\u003c\/p\u003e\u003cul data-start=\"2380\" data-end=\"2630\"\u003e\n\u003cli data-start=\"2380\" data-end=\"2400\"\u003e\u003cp data-start=\"2382\" data-end=\"2400\"\u003esubmersible pumps\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2401\" data-end=\"2429\"\u003e\u003cp data-start=\"2403\" data-end=\"2429\"\u003edomestic waterworks \/ Darling\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2430\" data-end=\"2455\"\u003e\u003cp data-start=\"2432\" data-end=\"2455\"\u003eself-priming pumps\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2456\" data-end=\"2474\"\u003e\u003cp data-start=\"2458\" data-end=\"2474\"\u003erotating machines\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2475\" data-end=\"2489\"\u003e\u003cp data-start=\"2477\" data-end=\"2489\"\u003ecompressors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2490\" data-end=\"2539\"\u003e\u003cp data-start=\"2492\" data-end=\"2539\"\u003eexhaust fans (carpentry, industry)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2566\"\u003e\u003cp data-start=\"2542\" data-end=\"2566\"\u003eproduction machines and systems\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2567\" data-end=\"2630\"\u003e\u003cp data-start=\"2569\" data-end=\"2630\"\u003eall devices where a record of total operating time is required\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"2632\" data-end=\"2740\" style=\"color: rgb(78, 86, 95);\"\u003eSuitable for maintenance intervals, maintenance planning, monitoring machine utilization, and recording the service life of equipment.\u003c\/p\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"DIN","offer_id":51204642341192,"sku":"DHM-DIN","price":30.69,"currency_code":"EUR","in_stock":true},{"title":"To the panel","offer_id":51204642373960,"sku":"DHM-48","price":30.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/file_9c09c481-48b9-4b09-8e88-2254bc3c7660.png?v=1755798378","url":"https:\/\/pelek-de.com\/en\/products\/betriebsstundenzahler-digital-mit-lcd-anzeige-230vac","provider":"Deutschland Pelek","version":"1.0","type":"link"}