{"product_id":"3-phasen-netzwerk-parameter-analysator-fur-netzfrequenz-spannung-und-strome-rs485","title":"3-phase network parameter analyzer for mains frequency, voltage and current RS485","description":"\u003ch1 data-start=\"90\" data-end=\"148\"\u003e\u003cstrong data-start=\"92\" data-end=\"146\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eThree-phase network parameter analyzer TPM-05 - TENSE\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003ch3 data-start=\"150\" data-end=\"163\"\u003e\u003cstrong data-start=\"154\" data-end=\"163\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDescription\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"164\" data-end=\"541\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe \u003cstrong data-start=\"174\" data-end=\"222\"\u003edigital three-phase multifunction meter TPM-05\u003c\/strong\u003e is designed for measuring and monitoring electrical parameters in three-phase systems. The device allows \u003cstrong data-start=\"321\" data-end=\"371\"\u003emonitoring of voltage, current, frequency, power\u003c\/strong\u003e and other advanced network quality analyses. With the \u003cstrong data-start=\"420\" data-end=\"440\"\u003eRS485 ModBus RTU\u003c\/strong\u003e, the analyzer can be connected to SCADA or other monitoring systems for remote data monitoring.\u003c\/font\u003e\u003c\/p\u003e\u003cp data-start=\"543\" data-end=\"684\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe TPM-05 analyzers enable comprehensive energy analysis, including \u003cstrong data-start=\"618\" data-end=\"681\"\u003ecalculation of efficiency, network quality, and unit costs\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\u003ch3 data-start=\"691\" data-end=\"712\"\u003e\u003cstrong data-start=\"695\" data-end=\"712\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey advantages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"713\" data-end=\"1461\"\u003e\n\u003cli data-start=\"713\" data-end=\"772\"\u003e\n\u003cp data-start=\"715\" data-end=\"772\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cstrong data-start=\"732\" data-end=\"752\"\u003eRS485 Modbus RTU\u003c\/strong\u003e communication port (1200-115200 bps)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"773\" data-end=\"834\"\u003e\n\u003cp data-start=\"775\" data-end=\"834\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of \u003cstrong data-start=\"785\" data-end=\"817\"\u003evoltage and current harmonics\u003c\/strong\u003e up to the 55th order\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"835\" data-end=\"944\"\u003e\n\u003cp data-start=\"837\" data-end=\"944\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePhase-wise display of \u003cstrong data-start=\"847\" data-end=\"867\"\u003eactive power\u003c\/strong\u003e (P) and \u003cstrong data-start=\"874\" data-end=\"893\"\u003ereactive power\u003c\/strong\u003e (Q, inductive and capacitive)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"945\" data-end=\"1017\"\u003e\n\u003cp data-start=\"947\" data-end=\"1017\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of \u003cstrong data-start=\"957\" data-end=\"978\"\u003eapparent power\u003c\/strong\u003e (S) and \u003cstrong data-start=\"985\" data-end=\"997\"\u003epower factor\u003c\/strong\u003e (Cosφ) for each phase\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1018\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1020\" data-end=\"1090\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMonitoring of \u003cstrong data-start=\"1033\" data-end=\"1053\"\u003eL-N and L-L voltage\u003c\/strong\u003e, current and \u003cstrong data-start=\"1064\" data-end=\"1077\"\u003efrequency\u003c\/strong\u003e of each phase\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1091\" data-end=\"1191\"\u003e\n\u003cp data-start=\"1093\" data-end=\"1191\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay of \u003cstrong data-start=\"1103\" data-end=\"1122\"\u003etotal energy\u003c\/strong\u003e: import\/export of active energy (ΣkWh) and reactive energy (ΣkVArh)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1192\" data-end=\"1260\"\u003e\n\u003cp data-start=\"1194\" data-end=\"1260\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRecording of \u003cstrong data-start=\"1201\" data-end=\"1237\"\u003eminimum and maximum values\u003c\/strong\u003e and maximum consumption\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1261\" data-end=\"1302\"\u003e\n\u003cp data-start=\"1263\" data-end=\"1302\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e2 relay outputs and 1 digital input\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1303\" data-end=\"1401\"\u003e\n\u003cp data-start=\"1305\" data-end=\"1401\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEvent logging: overvoltage\/undervoltage, overload, voltage\/current imbalance, THD-I, power outages\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1402\" data-end=\"1436\"\u003e\n\u003cp data-start=\"1404\" data-end=\"1436\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eReal-time \u003cstrong data-start=\"1413\" data-end=\"1434\"\u003eand date (RTC)\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1437\" data-end=\"1461\"\u003e\n\u003cp data-start=\"1439\" data-end=\"1461\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePassword-protected menu\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1468\" data-end=\"1497\"\u003e\u003cstrong data-start=\"1472\" data-end=\"1497\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"1498\" data-end=\"1852\"\u003e\n\u003cli data-start=\"1498\" data-end=\"1555\"\u003e\n\u003cp data-start=\"1500\" data-end=\"1555\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePower supply: depending on installation type (typically 3×230\/400 VAC)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1556\" data-end=\"1584\"\u003e\n\u003cp data-start=\"1558\" data-end=\"1584\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnection: terminal block\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1585\" data-end=\"1640\"\u003e\n\u003cp data-start=\"1587\" data-end=\"1640\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePanel dimensions: Standard 72×72 mm or depending on model\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1641\" data-end=\"1698\"\u003e\n\u003cp data-start=\"1643\" data-end=\"1698\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement accuracy: depending on harmonics and manufacturer parameters\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1699\" data-end=\"1779\"\u003e\n\u003cp data-start=\"1701\" data-end=\"1779\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCurrent transformers: 60\/5 to 1500\/5 A, or equivalent, recommended\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1780\" data-end=\"1852\"\u003e\n\u003cp data-start=\"1782\" data-end=\"1852\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eData acquisition and integration into \u003cstrong data-start=\"1817\" data-end=\"1826\"\u003eSCADA systems\u003c\/strong\u003e via ModBus RTU\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1859\" data-end=\"1874\"\u003e\u003cstrong data-start=\"1863\" data-end=\"1874\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"1875\" data-end=\"1909\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe TPM-05 analyzer is suitable for:\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\u003c\/p\u003e\u003cul data-start=\"1910\" data-end=\"2076\"\u003e\n\u003cli data-start=\"1910\" data-end=\"1948\"\u003e\n\u003cp data-start=\"1912\" data-end=\"1948\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndustrial distribution and production facilities\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1949\" data-end=\"1986\"\u003e\n\u003cp data-start=\"1951\" data-end=\"1986\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCommercial buildings, schools, hospitals\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1987\" data-end=\"2027\"\u003e\n\u003cp data-start=\"1989\" data-end=\"2027\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMonitoring energy quality and energy consumption\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2028\" data-end=\"2076\"\u003e\n\u003cp data-start=\"2030\" data-end=\"2076\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMonitoring the efficiency of electrical devices\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":51204706566472,"sku":"TPM-05","price":217.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/9551\/2136\/files\/16c0d0e55d8b29ad8d31c44a4c22d5a0.png?v=1755800303","url":"https:\/\/pelek-de.com\/en\/products\/3-phasen-netzwerk-parameter-analysator-fur-netzfrequenz-spannung-und-strome-rs485","provider":"Deutschland Pelek","version":"1.0","type":"link"}